Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Jul 10;319(7202):83-6.
doi: 10.1136/bmj.319.7202.83.

Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database

Affiliations

Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database

J M Evans et al. BMJ. .

Abstract

Objectives: To investigate patterns of self monitoring of blood glucose concentration in diabetic patients who use insulin and to determine whether frequency of self monitoring is related to glycaemic control.

Setting: Diabetes database, Tayside, Scotland.

Subjects: Patients resident in Tayside in 1993-5 who were using insulin and were registered on the database and diagnosed with insulin dependent (type 1) or non-insulin dependent (type 2) diabetes before 1993.

Main outcome measures: Number of glucose monitoring reagent strips dispensed (reagent strip uptake) derived from records of prescriptions. First recorded haemoglobin A1c concentration in the study period, and reagent strips dispensed in the previous 6 months.

Results: Among 807 patients with type 1 diabetes, 128 (16%) did not redeem any prescriptions for glucose monitoring reagent strips in the 3 year study period. Only 161 (20%) redeemed prescriptions for enough reagent strips to test glucose daily. The corresponding figures for the 790 patients with type 2 diabetes who used insulin were 162 (21%; no strips) and 131 (17%; daily tests). Reagent strip uptake was influenced both by age and by deprivation category. There was a direct relation between uptake and glycaemic control for 258 patients (with recorded haemoglobin A1c concentrations) with type 1 diabetes. In a linear regression model the decrease in haemoglobin A1c concentration for every extra 180 reagent strips dispensed was 0.7%. For the 290 patients with type 2 diabetes who used insulin there was no such relation.

Conclusions: Self monitoring of blood glucose concentration is associated with improved glycaemic control in patients with type 1 diabetes. Regular self monitoring in patients with type 1 and type 2 diabetes is uncommon.

PubMed Disclaimer

References

    1. DCCT Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. New Engl J Med. 1989;329:977–986. - PubMed
    1. UK Prospective Diabetes Study (UKPDS) Group. Intensive blood glucose control with sulphonylureas or insulin compared with conventional treatment and the risk of complications in patients with type 2 diabetes (UKPDS 33) Lancet. 1998;352:837–853. - PubMed
    1. Consensus statement on self-monitoring of blood glucose. Diabetes Care. 1987;10:95–97. - PubMed
    1. American Diabetes Association. Consensus statement on self-monitoring of blood glucose. Diabetes Care. 1994;17:81–86. - PubMed
    1. Harris MI, Cowie CC, Howie LJ. Self-monitoring of blood glucose by adults with diabetes in the United States population. Diabetes Care. 1993;16:1116–1123. - PubMed

Publication types