Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Mar;29(3):245-52.
doi: 10.1016/s0720-048x(98)00169-7.

T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging

Affiliations
Free article

T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging

H Hatabu et al. Eur J Radiol. 1999 Mar.
Free article

Abstract

Objective: To obtain T2* and proton density measurements of normal human lung parenchyma in vivo using submillisecond echo time (TE) gradient echo (GRE) magnetic resonance (MR) imaging.

Materials and methods: Six normal volunteers were scanned using a 1.5-T system equipped with a prototype enhanced gradient (GE Signa, Waukausha, WI). Images were obtained during breath-holding with acquisition times of 7-16 s. Multiple TEs ranging from 0.7 to 2.5 ms were tested. Linear regression was performed on the logarithmic plots of signal intensity versus TE, yielding measurements of T2* and proton density relative to chest wall muscle. Measurements in supine and prone position were compared, and effects of the level of lung inflation on lung signal were also evaluated.

Results: The signal from the lung parenchyma diminished exponentially with prolongation of TE. The measured T2* in six normal volunteers ranged from 0.89 to 2.18 ms (1.43 +/- 0.41 ms, mean +/- S.D.). The measured relative proton density values ranged between 0.21 and 0.45 (0.29 +/- 0.08, mean +/- S.D.). Calculated T2* values of 1.46 +/- 0.50, 1.01 +/- 0.29 and 1.52 +/- 0.18 ms, and calculated relative proton densities of 0.20 +/- 0.03, 0.32 +/- 0.13 and 0.35 +/- 0.10 were obtained from the anterior, middle and posterior portions of the supine right lung, respectively. The anterior-posterior proton density gradient was reversed in the prone position. There was a pronounced increase in signal from lung parenchyma at maximum expiration compared with maximum inspiration. The ultrashort TE GRE technique yielded images demonstrating signal from lung parenchyma with minimal motion-induced noise.

Conclusion: Quantitative in vivo measurements of lung T2* and relative proton density in conjunction with high-signal parenchymal images can be obtained using a set of very rapid breath-hold images with a recently developed ultrashort TE GRE sequence.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources