Clinical Trial
. 1999 Jul;25(7):911-20.
doi: 10.1016/s0886-3350(99)00072-3.

One year clinical results of photoastigmatic refractive keratectomy for compound myopic astigmatism

Affiliations
Clinical Trial

One year clinical results of photoastigmatic refractive keratectomy for compound myopic astigmatism

J L Febbraro et al. J Cataract Refract Surg. 1999 Jul.

Abstract

Purpose: To evaluate the efficacy, predictability, and safety of excimer laser photoastigmatic refractive keratectomy (PARK) to correct compound myopic astigmatism.

Setting: Departments of Ophthalmology, Robert Debré Hospital and Rothschild Foundation, Paris, France.

Methods: This retrospective study included 27 eyes with compound myopic astigmatism treated with a Nidek EC 5000 excimer laser. The refractive results were measured at 1 year, and the cylindrical component was analyzed by the Alpins method. Mean preoperative myopia was -4.50 diopters (D) (range -0.75 to -4.00 D) and mean preoperative cylinder, -1.64 D (range -0.75 to -4.00 D).

Results: At 1 year, the spherical equivalent was -0.47 D (range +1.00 to -3.00 D) and residual subjective astigmatism, -0.40 (range -0.25 to -1.50 D). Uncorrected visual acuity of 20/40 or better was obtained in 22 of the 27 eyes; 21 eyes were within +/- 1.0 D of emmetropia. Vector analysis showed a mean coefficient adjustment of 1.50 D +/- 0.53 (SD), a mean axis shift of 2.64 +/- 12.10 degrees, and a mean magnitude of error of 0.45 +/- 0.56 D. Haze was absent in 22 eyes and grade 1+ in 5 eyes. Five eyes gained 1 line of best corrected visual acuity and 3 lost 1 line. No patient lost more than 1 line.

Conclusion: Excimer laser PARK successfully corrected low and moderate myopia combined with up to 4.0 D of astigmatism with a low mean angle of error. To increase the accuracy of toric ablation, specific algorithms for the cylinder component are needed.