Detection failures in spiral CT screening for lung cancer: analysis of CT findings
- PMID: 10405721
- DOI: 10.1148/radiology.212.1.r99jn1461
Detection failures in spiral CT screening for lung cancer: analysis of CT findings
Abstract
Purpose: To clarify the computed tomographic (CT) findings and the progression of minute lung cancers that were missed at initial spiral CT screening but were later detected.
Materials and methods: The findings from seven patients with lung cancer that was missed at the initial spiral CT screening were reviewed. Retrospective CT findings, time to detection, cell type, and pathologic stage were evaluated.
Results: Minute lung cancers missed at early spiral CT included a nodule among the shadows of old tuberculosis (n = 2), a faint nodule with high attenuation in the center of the nodule (n = 1), an increase in attenuation just adjacent to an axial peripheral pulmonary vessel (n = 1) and adjacent to a craniocaudal peripheral pulmonary vessel (n = 1), and a minute faint nodule (n = 2). The time to detection ranged from 6 to 18 months. At pathologic examination, six cancers were stage I, and one was stage II.
Conclusion: Minute nodules of lung cancer that are near the threshold of detectability may be missed at spiral CT screening. It is important to examine noncalcified nodules with thin-section CT even when lesions from prior disease, such as those from old tuberculosis, exist and to evaluate the shadows of pulmonary vessels carefully. A follow-up examination is highly recommended.
Similar articles
-
Malignant versus benign nodules at CT screening for lung cancer: comparison of thin-section CT findings.Radiology. 2004 Dec;233(3):793-8. doi: 10.1148/radiol.2333031018. Epub 2004 Oct 21. Radiology. 2004. PMID: 15498895
-
Characteristics of small lung cancers invisible on conventional chest radiography and detected by population based screening using spiral CT.Br J Radiol. 2000 Feb;73(866):137-45. doi: 10.1259/bjr.73.866.10884725. Br J Radiol. 2000. PMID: 10884725
-
Lung cancers missed at low-dose helical CT screening in a general population: comparison of clinical, histopathologic, and imaging findings.Radiology. 2002 Dec;225(3):673-83. doi: 10.1148/radiol.2253011375. Radiology. 2002. PMID: 12461245
-
Limitations of screening for lung cancer with low-dose spiral computed tomography.Clin Cancer Res. 2005 Jul 1;11(13 Pt 2):4988s-4992s. doi: 10.1158/1078-0432.CCR-05-9000. Clin Cancer Res. 2005. PMID: 16000601 Review.
-
[Clinical analysis of primary lung cancer with a thin-walled cavity to explain the mechanism of thin-walled cavity formation].Nihon Kokyuki Gakkai Zasshi. 2007 Jun;45(6):460-4. Nihon Kokyuki Gakkai Zasshi. 2007. PMID: 17644941 Review. Japanese.
Cited by
-
Commercial CT scans: VOMIT victim of medical investigative technology.BMJ. 2008 Jan 5;336(7634):8. doi: 10.1136/bmj.39435.572731.3A. BMJ. 2008. PMID: 18174573 Free PMC article. No abstract available.
-
Screening for lung cancer.Cochrane Database Syst Rev. 2013 Jun 21;2013(6):CD001991. doi: 10.1002/14651858.CD001991.pub3. Cochrane Database Syst Rev. 2013. PMID: 23794187 Free PMC article.
-
Reply to commentary--'CT radiation dose reduction: can we do harm by doing good?'.Pediatr Radiol. 2012 Apr;42(4):399-401. doi: 10.1007/s00247-011-2331-9. Pediatr Radiol. 2012. PMID: 22302319 No abstract available.
-
Using the CT features to differentiate invasive pulmonary adenocarcinoma from pre-invasive lesion appearing as pure or mixed ground-glass nodules.Br J Radiol. 2015 Sep;88(1053):20140811. doi: 10.1259/bjr.20140811. Epub 2015 Jun 19. Br J Radiol. 2015. PMID: 26090823 Free PMC article.
-
Validation of a deep learning computer aided system for CT based lung nodule detection, classification, and growth rate estimation in a routine clinical population.PLoS One. 2022 May 5;17(5):e0266799. doi: 10.1371/journal.pone.0266799. eCollection 2022. PLoS One. 2022. PMID: 35511758 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical