Effects of size and shape (aspect ratio) on the hemodynamics of saccular aneurysms: a possible index for surgical treatment of intracranial aneurysms
- PMID: 10414574
- DOI: 10.1097/00006123-199907000-00028
Effects of size and shape (aspect ratio) on the hemodynamics of saccular aneurysms: a possible index for surgical treatment of intracranial aneurysms
Abstract
Objective: The present study was undertaken to explore the relationship between the characteristic geometry of aneurysms prone to rupture and the blood flow patterns therein, using microsurgically produced aneurysms that simulated human middle cerebral artery aneurysms in scale and shape.
Methods: We measured in vivo velocity profiles using our 20-MHz, 80-channel, Doppler ultrasound velocimeter. We produced small (< or =5 mm, 5 cases) and large (6-13 mm, 12 cases) aneurysms with round, dumbbell, or multilobular shapes.
Results: The fundamental patterns of intra-aneurysmal flow were composed of inflow, circulating flow, and outflow. The inflow, which entered the aneurysm only during the systolic phase, was strongly influenced by the position and size of the neck and the flow ratio into the distal branches. The outflow was usually nonpulsatile and of low velocity. The circulating flow depended on the aspect ratio (depth/neck width). A single recirculation zone was observed in aneurysms with aspect ratios of less than 1.6. This circulation did not seem to extend to areas with aspect ratios greater than this value; in aneurysms with aspect ratios of more than 1.6, a much slower circulation was observed near the dome. Furthermore, in the dome of dumbbell-shaped aneurysms and daughter aneurysms, no flow was detected. Intra-aneurysmal flow was determined by the aspect ratio, rather than the aneurysm size.
Conclusion: The localized, extremely low-flow condition that was observed in the dome of aneurysms with aspect ratios of more than 1.6 is a common flow characteristic in the geometry of ruptured aneurysms, so great care should be taken for patients with unruptured intracranial aneurysms with aspect ratios of more than 1.6.
Similar articles
-
Aneurysm inflow-angle as a discriminant for rupture in sidewall cerebral aneurysms: morphometric and computational fluid dynamic analysis.Stroke. 2010 Jul;41(7):1423-30. doi: 10.1161/STROKEAHA.109.570770. Epub 2010 May 27. Stroke. 2010. PMID: 20508183
-
Quantification of hemodynamic irregularity using oscillatory velocity index in the associations with the rupture status of cerebral aneurysms.J Neurointerv Surg. 2019 Jun;11(6):614-617. doi: 10.1136/neurintsurg-2018-014489. Epub 2019 Jan 22. J Neurointerv Surg. 2019. PMID: 30670624
-
[Rheological characteristics of the aneurysm at the middle cerebral artery bifurcation].No Shinkei Geka. 2001 Oct;29(10):921-30. No Shinkei Geka. 2001. PMID: 11681008 Japanese.
-
Selection of cerebral aneurysms for treatment using Guglielmi detachable coils: the preliminary University of Illinois at Chicago experience.Neurosurgery. 1998 Dec;43(6):1281-95; discussion 1296-7. doi: 10.1097/00006123-199812000-00011. Neurosurgery. 1998. PMID: 9848841 Review.
-
Ruptured aneurysm of the PICA communicating artery: a case report.J Stroke Cerebrovasc Dis. 2014 May-Jun;23(5):1247-52. doi: 10.1016/j.jstrokecerebrovasdis.2013.08.014. Epub 2013 Oct 8. J Stroke Cerebrovasc Dis. 2014. PMID: 24119627 Review.
Cited by
-
Assessment of Interrater Reliability and Accuracy of Cerebral Aneurysm Morphometry Using 3D Virtual Reality, 2D Digital Subtraction Angiography, and 3D Reconstruction: A Randomized Comparative Study.Brain Sci. 2024 Sep 26;14(10):968. doi: 10.3390/brainsci14100968. Brain Sci. 2024. PMID: 39451982 Free PMC article.
-
Comparison of computational fluid dynamics findings with intraoperative microscopy findings in unruptured intracranial aneurysms- An initial analysis.Asian J Neurosurg. 2016 Oct-Dec;11(4):356-360. doi: 10.4103/1793-5482.180962. Asian J Neurosurg. 2016. PMID: 27695537 Free PMC article.
-
Hemodynamics of cerebral aneurysms: computational analyses of aneurysm progress and treatment.Comput Math Methods Med. 2012;2012:782801. doi: 10.1155/2012/782801. Epub 2012 Feb 19. Comput Math Methods Med. 2012. PMID: 22454695 Free PMC article. Review.
-
Technical feasibility of embolizing aneurysms with glue (N-butyl 2-cyanoacrylate): experimental study in rabbits.AJNR Am J Neuroradiol. 2003 Sep;24(8):1532-9. AJNR Am J Neuroradiol. 2003. PMID: 13679265 Free PMC article.
-
Hemodynamic and Morphological Parameters of Ruptured Mirror Posterior Communicating Artery Aneurysms.Front Neurol. 2021 Sep 27;12:653589. doi: 10.3389/fneur.2021.653589. eCollection 2021. Front Neurol. 2021. PMID: 34646225 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical