Anesthetic gas exposure in veterinary clinics
- PMID: 10429733
- DOI: 10.1080/104732299302783
Anesthetic gas exposure in veterinary clinics
Abstract
Concerns were raised by several workers from veterinary clinics in Manitoba, Canada, regarding potential exposure to isoflurane and halothane during anesthetic administration. There has been no guideline established for isoflurane by the American Conference of Governmental Industrial Hygienist (ACGIH) or a Permissible Exposure Limit by the Occupational Safety and Health Administration (OSHA) or a recommended exposure limit (REL) by the National Institute for Occupational Safety and Health (NIOSH). The ACGIH TLV-TWA for halothane is 50 ppm and NIOSH has established 2 ppm as a recommended level based on an one-hour sampling. OSHA has established no guideline for halothane. The Miran IB Portable Ambient Air Analyzer was used to conduct real-time sampling and to identify leaks during administration. All veterinary clinics inspected had installed the passive waste gas scavenging system. Ten clinics were each monitored during anesthetic gas delivery for one surgical procedure performed. Induction was 4 to 5 percent and maintenance 1.5 to 2.5 percent. Nine clinics were small animal practices and the tenth was an equine clinic. Veterinarians' personal exposures were higher than the assistants'. Veterinarians' personal exposures for isoflurane ranged from 1.3 to 13 ppm (AM = 5.3; SD +/- 2.7; GM = 4.6; GSD +/- 1.6) and for their assistants, personal exposures ranged from 1.2 to 9 ppm (AM = 4.7; SD +/- 2.5; GM = 3.9; GSD +/- 1.6). Veterinarians' personal exposures for halothane ranged from 0.7 to 12 ppm (AM = 4.2; SD +/- 3.6; GM = 2.9; GSD +/- 1.4) and for their assistants, personal exposures ranged from 0.4 to 3.2 ppm (AM = 1.8; SD +/- 1.0; GM = 1.5; GSD +/- 1.7). One clinic had significant leaks in the anesthetic gas delivery lines. Personal halothane exposure for the veterinarian at this clinic was 7.2 to 65 ppm (AM = 18.0; SD +/- 11.5; GM = 15.9; GSD +/- 1.8). Based on this study, worker exposures were acceptable. Peak exposures were recorded when the cuffed endotracheal tube was removed from the animal. Equipment leaks were minimal when the system was maintained at its optimum operating condition.
Similar articles
-
Real-time measurement and control of waste anesthetic gases during veterinary surgeries.Am Ind Hyg Assoc J. 1990 Dec;51(12):640-5. doi: 10.1080/15298669091370284. Am Ind Hyg Assoc J. 1990. PMID: 2270831
-
Occupational health concerns in the welding industry.Appl Occup Environ Hyg. 2000 Dec;15(12):936-45. doi: 10.1080/104732200750051175. Appl Occup Environ Hyg. 2000. PMID: 11141606
-
Waste anesthetic gas and vapor exposures in veterinary hospitals and clinics.Am Ind Hyg Assoc J. 1980 Mar;41(3):229-31. doi: 10.1080/15298668091424663. Am Ind Hyg Assoc J. 1980. PMID: 7395736
-
[Anesthetic gas contamination in the operating room--an unsolved problem? Results of our own studies].Anaesthesist. 1991 Nov;40(11):629-37. Anaesthesist. 1991. PMID: 1755534 Review. German.
-
Limitations of occupational air contaminant standards, as exemplified by the neurotoxin N-hexane.J Public Health Policy. 1999;20(4):441-58. J Public Health Policy. 1999. PMID: 10643170 Review.
Cited by
-
Trends in exposure of veterinarians to physical and chemical hazards and use of protection practices.Int Arch Occup Environ Health. 2008 Jan;81(3):371-8. doi: 10.1007/s00420-007-0221-0. Epub 2007 Jul 21. Int Arch Occup Environ Health. 2008. PMID: 17643262
-
Review of hazards to female reproductive health in veterinary practice.J Am Vet Med Assoc. 2017 Apr 15;250(8):862-872. doi: 10.2460/javma.250.8.862. J Am Vet Med Assoc. 2017. PMID: 28358639 Free PMC article. Review.
-
Field application of SPME as a novel tool for occupational exposure assessment with inhalational anesthetics.Environ Monit Assess. 2012 Nov;184(11):6483-90. doi: 10.1007/s10661-011-2434-7. Epub 2011 Nov 18. Environ Monit Assess. 2012. PMID: 22089627
-
Measurement of anesthetic pollution in veterinary operating rooms for small animals: Isoflurane pollution in a university veterinary hospital.Braz J Anesthesiol. 2021 Sep-Oct;71(5):517-522. doi: 10.1016/j.bjane.2021.02.007. Epub 2021 Feb 3. Braz J Anesthesiol. 2021. PMID: 33685758 Free PMC article.
-
Waste anesthetic gas exposure and strategies for solution.J Anesth. 2018 Apr;32(2):269-282. doi: 10.1007/s00540-018-2448-1. Epub 2018 Feb 5. J Anesth. 2018. PMID: 29404778 Review.
MeSH terms
Substances
LinkOut - more resources
Medical