A comparison of inductively coupled plasma mass spectrometry with electrothermal atomic absorption spectrophotometry for the determination of trace elements in blood and urine from non occupationally exposed populations
- PMID: 10445225
- DOI: 10.1016/S0946-672X(99)80030-3
A comparison of inductively coupled plasma mass spectrometry with electrothermal atomic absorption spectrophotometry for the determination of trace elements in blood and urine from non occupationally exposed populations
Abstract
Quadrupole Inductively coupled plasma mass spectrometric (QICP-MS) and electrothermal atomic absorption spectrophotometric (ETAAS) methods for the determination of Pb and Cd in whole blood and Al, Cd, Co and Ni in urine were compared. Simple sample pretreatments were used for both instrumental techniques. Urine samples were diluted with either Millipore water or dilute HNO3, while blood samples were diluted with a solution containing either 0.14M NH3 or 0.03 M NH3, 0.05% EDTA and 0.05% Triton X-100 in Millipore water. Scandium, yttrium and indium were used as internal standards for ICP-MS measurements and (NH4)2HPO4 as a chemical modifier for the determination of Pb and Cd by ETAAS. For ICP-MS analysis, pneumatic nebulization was used for introduction of urine samples and flow injection for introduction of blood samples. Matrix matched standards were used for all calibrations and methods were validated by analyzing reference materials and samples from external quality assurance programmes. Concentrations of the listed metals were determined in blood and urine samples obtained from a healthy non occupationally exposed population and reference samples, using both instrumental techniques. The study group (n = 90) was randomly selected from a study population (n = 220) recruited from three regions considered representative of the environment encountered by the majority of the United Kingdom population. Males and females were equally represented and ranged in age from 17-65 yrs. The correlation between results obtained by the two techniques was good for all elements measured, ranging from r = 0.88 for Co in urine to r = 0.99 for both Pb and Cd in blood.
Similar articles
-
Biomonitoring of 20 trace elements in blood and urine of occupationally exposed workers by sector field inductively coupled plasma mass spectrometry.Talanta. 2013 Nov 15;116:764-9. doi: 10.1016/j.talanta.2013.07.079. Epub 2013 Aug 7. Talanta. 2013. PMID: 24148471
-
Validation of a method to quantify chromium, cadmium, manganese, nickel and lead in human whole blood, urine, saliva and hair samples by electrothermal atomic absorption spectrometry.Anal Chim Acta. 2010 Feb 5;659(1-2):60-7. doi: 10.1016/j.aca.2009.11.056. Epub 2009 Dec 1. Anal Chim Acta. 2010. PMID: 20103106
-
Biomonitoring of 37 trace elements in blood samples from inhabitants of northern Germany by ICP-MS.J Trace Elem Med Biol. 2006;20(4):253-62. doi: 10.1016/j.jtemb.2006.08.001. Epub 2006 Sep 27. J Trace Elem Med Biol. 2006. PMID: 17098585
-
[Inductively coupled plasma atomic emission spectrometry and ICP mass spectrometry].Nihon Rinsho. 1996 Jan;54(1):202-6. Nihon Rinsho. 1996. PMID: 8587191 Review. Japanese.
-
Evaluation of methods for trace-element determination with emphasis on their usability in the clinical routine laboratory.Scand J Clin Lab Invest. 2007;67(4):353-66. doi: 10.1080/00365510601095281. Scand J Clin Lab Invest. 2007. PMID: 17558890 Review.
Cited by
-
Cadmium, chromium, lead, manganese and nickel concentrations in blood of women in non-polluted areas in Japan, as determined by inductively coupled plasma-sector field-mass spectrometry.Int Arch Occup Environ Health. 2011 Feb;84(2):139-50. doi: 10.1007/s00420-010-0542-2. Epub 2010 Jun 3. Int Arch Occup Environ Health. 2011. PMID: 20521063
-
Relation Between Lead Exposure and Trends in Blood Pressure in Children.Am J Cardiol. 2018 Dec 1;122(11):1890-1895. doi: 10.1016/j.amjcard.2018.08.033. Epub 2018 Sep 7. Am J Cardiol. 2018. PMID: 30292331 Free PMC article.
-
Are Serum Metal Ion Levels a Concern at Mid-term Followup of Revision Knee Arthroplasty With a Metal-on-metal Hinge Design?Clin Orthop Relat Res. 2019 Sep;477(9):2007-2014. doi: 10.1097/CORR.0000000000000638. Clin Orthop Relat Res. 2019. PMID: 30811355 Free PMC article.
-
Estimation of daily selenium intake by 3- to 5-year-old Japanese children based on selenium excretion in 24-h urine samples.J Nutr Sci. 2019 Jul 24;8:e24. doi: 10.1017/jns.2019.21. eCollection 2019. J Nutr Sci. 2019. PMID: 31428331 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources