Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Jul;11(3):244-9.
doi: 10.1016/s1043-0679(99)70065-1.

Computer-enhanced mitral valve surgery: toward a total endoscopic procedure

Affiliations

Computer-enhanced mitral valve surgery: toward a total endoscopic procedure

V Falk et al. Semin Thorac Cardiovasc Surg. 1999 Jul.

Abstract

The aim of the study was to develop a computer-enhanced, video-assisted approach for mitral valve repair as a potential step toward a complete endoscopic procedure. In 10 patients with nonischemic mitral valve insufficiency, computer-enhanced telemetric mitral valve repair using the Intuitive surgical telemanipulation system was performed. A femorofemoral bypass was initiated using Port-Access (Heartport, Redwood City, CA) cannulation. A small minithoracotomy was made in the right 4th intercostal space, and a custom-made rib retractor was placed. The pericardium was opened manually, and four traction stay sutures were placed to enhance exposure. After endoaortic balloon clamping, the left atrium was opened and stabilized. The end-effectors were placed in the left atrium through two ports (3rd ICS and 6th ICS, midaxillary line). A 30 degrees three-dimensional (3D)-videoscope angled up was placed through the incision. Mitral valve repair was then performed remotely from the surgical console. This included inspection of the valve, leaflet resection, leaflet repair, and ring implantation. After completion of the repair and testing of the valve, the end effectors were withdrawn, and the left atrium was closed manually using standard endoscopic instruments (Heartport). In all but 1 patient, successful repair, including quadrangular resection, chordal shortening, Whooler-plasty, and Alfieri-plasty, could be accomplished using the computer-enhanced telemanipulation system. A partial ring was implanted in 6 patients and a complete ring was implanted in 3 patients, respectively. Time for surgery, CPB, and clamp time were 170 to 330 minutes (median, 185 minutes), 140 to 220 minutes (median, 149 minutes), and 78 to 133 minutes (median, 94 minutes), respectively. In one patient, intraoperative transesophageal echocardiography (TEE) showed insufficient repair, a second surgery was performed via an enlarged left thoracotomy. One patient with recurrent mitral insufficiency had to have a second surgery on postoperative day 3 for a torn-out ring. Median time of hospitalization was 8 days. At 3 months follow-up (completed in 7 patients), all patients had improved clinically. Computer-enhanced mitral valve repair is feasible and can be performed with good functional results. The telemanipulation system offers the potential for true endoscopic mitral valve repair. However, surgical time is prolonged, and a learning curve has to be overcome.

PubMed Disclaimer

LinkOut - more resources