Foreign body reaction to meshes used for the repair of abdominal wall hernias
- PMID: 10452261
- DOI: 10.1080/11024159950189726
Foreign body reaction to meshes used for the repair of abdominal wall hernias
Abstract
Objective: To investigate the local tissue reactions to meshes that had been removed from humans.
Design: Open study
Setting: Surgical department of the technical University, Aachen, Germany.
Material: Samples of 17 non-absorbable meshes (1 polyester, 10 polypropylene, 2 reduced polypropylene, and 4 polytetrafluorethylene, PTFE) and 1 absorbable mesh (polyglactin 910) that had been implanted for repair of abdominal wall defects.
Interventions: Light and transmission electron microscopy, immunohistochemistry, and histological examination.
Main outcome measures: Signs of inflammatory response.
Results: Light microscopy showed chronic inflammatory tissue reaction, even after years, with pronounced differences among materials. Partial volume of inflammatory cells (%) varied from 32 in polypropylene, to 12 in expanded PTFE, 8 in polyester, and 7 in reduced polypropylene. Formation of connective tissue correlated significantly with the extent of the inflammatory reaction (p<0.01). In meshes implanted for long periods there were still numerous macrophages at the interface between tissue and polypropylene (45%), polyester (45%), expanded PTFE (25%), and reduced polypropylene (22%). There was no difference in time dependent tissue reactions (p = 0.19).
Conclusion: Inflammation around alloplastic materials used to repair defects in the abdominal wall persists for many years. There was evidence of long term wound complications as a result of persistent foreign body reactions. Further studies are required to evaluate the long term tissue response to these materials.
Similar articles
-
Introduction of polyethylene terephthalate mesh (KoSa hochfest) for abdominal hernia repair: an animal experimental study.Biomed Mater Eng. 2004;14(2):127-32. Biomed Mater Eng. 2004. PMID: 15156103
-
Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall.Eur J Surg. 1998 Dec;164(12):951-60. doi: 10.1080/110241598750005138. Eur J Surg. 1998. PMID: 10029391
-
Textile analysis of heavy weight, mid-weight, and light weight polypropylene mesh in a porcine ventral hernia model.J Surg Res. 2006 Nov;136(1):1-7. doi: 10.1016/j.jss.2006.05.022. Epub 2006 Sep 22. J Surg Res. 2006. PMID: 16996087
-
[Development of better tolerated prosthetic materials: applications in gynecological surgery].J Gynecol Obstet Biol Reprod (Paris). 2002 Oct;31(6):527-40. J Gynecol Obstet Biol Reprod (Paris). 2002. PMID: 12407323 Review. French.
-
[Meshes within the abdominal wall].Chirurg. 1999 Aug;70(8):876-87. Chirurg. 1999. PMID: 10460281 Review. German.
Cited by
-
The use of nontreated mosquito-net mesh cloth for a tension free inguinal hernia repair: our experience.Niger J Surg. 2015 Jan-Jun;21(1):48-51. doi: 10.4103/1117-6806.152726. Niger J Surg. 2015. PMID: 25838767 Free PMC article.
-
Meta-analysis of randomized controlled trials comparing lightweight and heavyweight mesh for Lichtenstein inguinal hernia repair.Hernia. 2012 Oct;16(5):505-18. doi: 10.1007/s10029-012-0901-x. Epub 2012 Feb 28. Hernia. 2012. PMID: 22371213
-
Evaluation of a fully absorbable poly-4-hydroxybutyrate/absorbable barrier composite mesh in a porcine model of ventral hernia repair.Surg Endosc. 2016 Sep;30(9):3691-701. doi: 10.1007/s00464-016-5057-9. Epub 2016 Jul 1. Surg Endosc. 2016. PMID: 27369286 Free PMC article.
-
Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat.Hernia. 2005 Dec;9(4):322-9. doi: 10.1007/s10029-005-0009-7. Epub 2005 Aug 2. Hernia. 2005. PMID: 16075158
-
Chronic posterior seroma with neoperitoneum following laparoscopic ventral hernia repair: treatment algorithm.Hernia. 2008 Aug;12(4):363-6. doi: 10.1007/s10029-008-0350-8. Epub 2008 Feb 8. Hernia. 2008. PMID: 18259834
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources