Clinical Trial
. 1999 Aug;31(2):347-53.
doi: 10.1016/s0168-8278(99)80234-7.

MRI guidance of infra-red laser liver tumour ablations, utilising an open MRI configuration system: technique and early progress

Affiliations
Clinical Trial

MRI guidance of infra-red laser liver tumour ablations, utilising an open MRI configuration system: technique and early progress

M G de Jode et al. J Hepatol. 1999 Aug.

Abstract

Background/aims: Primary and secondary liver tumours are a common clinical problem, with a poor prognosis in most cases. Surgical resection offers the best outcome, but is only appropriate for the minority. Thermal ablation techniques have been described, but the lack of an optimal means of monitoring has limited their use. We undertook a pilot study to assess the feasibility and safety of an integrated MR-guided laser thermoablation technique under local anaesthesia using a real-time colourisation thermal monitoring technique in a newly developed open MR scanner.

Methods: Liver tumours were punctured after the administration of intravenous Mangafodipir trisodium (MnDPDP) using real-time MR image guidance under local or general anaesthesia, and treated using a water-cooled interstitial fibre and a Nd-YAG laser source. Twenty-seven procedures were performed in 12 patients. Therapy was monitored using a real-time MR colourisation sequence. Thermoablation was followed by a colour change in a region of interest.

Results: Thermal lesions of mean size 3 cm in diameter were produced with a maximum size of 5 cm. Eight out of 12 patients were discharged the next day with few significant complications. Repeat procedures have been performed in seven of 12 patients. Two patients with lesions of 3 cm diameter have had complete tumour ablation with only one procedure.

Conclusion: Percutaneous laser thermoablation for liver tumours performed as an integrated one-step technique in an open configuration MR scanner is described. It can be safely performed under local anaesthesia in the majority of patients, with few side effects. MR control shows the site and size of the evolving thermal lesions, allowing appropriate action to be taken in terms of further burns, time of application and power applied.