Microdamage adjacent to endosseous implants
- PMID: 10456388
- DOI: 10.1016/s8756-3282(99)00151-9
Microdamage adjacent to endosseous implants
Abstract
Intense remodeling occurs in lamellar bone adjacent to osseointegrated endosseous implants. The purpose of this study was to compare microdamage accumulation subsequent to ex vivo fatigue loading of bone that surrounds an endosseous implant, (a) immediately after placement (nonadapted bone) and (b) following a 12 week healing period after placement (adapted bone). We hypothesize that there is less microdamage in the more compliant adapted bone than in the older nonadapted bone. Nonthreaded titanium plasma sprayed (TPS)-coated endosseous implants were placed into dog mid-femoral diaphyses and allowed to heal for 12 weeks. Block sections of bone, each containing one implant, were cut anteroposteriorly, resulting in an implant containing lateral cortex, and a medial cortex that was used for testing the nonadapted specimens. Control specimens (n = 14 each for adapted and nonadapted) were loaded at 0 N. Experimental specimens (n = 13, adapted; n = 14, nonadapted) were loaded at 100 N in cantilever bending for 150,000 cycles at 2 Hz, at 37 degrees C on a Bionix 858 testing machine. Specimens were bulk stained with basic fuchsin and 120-140 microm sections were obtained. Crack numerical density (Cr.Dn = Cr.N/ B.Ar, #/mm2), crack surface density (Cr.S.Dn = Tt.Cr.Le/ B.Ar, mm/mm2), and percent damage area (Dm.Ar = Cr.Ar x 100/B.Ar, mm2/mm2) were measured at x 250. Statistically significant differences (p < 0.0001) were seen for Cr.Dn, Cr.S.Dn, and Dm.Ar on the compressed cortices suggesting that adapted bone near the implant accumulated significantly less microdamage than nonadapted bone. Also, the adapted nonloaded control specimens had approximately 20-fold less damage than the respective nonadapted specimens. This study suggests that the compliant adapted bone adjacent to endosseous implants is relatively resistant to fatigue loads. The high success rates of endosseous implants may be due to the presence of a rapidly remodeling region that maintains tissue compliance and limits microdamage initiation.
Similar articles
-
Development of a fluorescent light technique for evaluating microdamage in bone subjected to fatigue loading.J Biomech. 1999 Nov;32(11):1243-9. doi: 10.1016/s0021-9290(99)00047-0. J Biomech. 1999. PMID: 10541076
-
Evaluation of titanium plasma-sprayed and plasma-sprayed hydroxyapatite implants in vivo.Biomaterials. 2004 Aug;25(19):4601-6. doi: 10.1016/j.biomaterials.2003.11.053. Biomaterials. 2004. PMID: 15120505
-
Osseointegration of a hydroxyapatite-coated multilayered mesh stem.Biomaterials. 2004 Jul;25(15):2957-69. doi: 10.1016/j.biomaterials.2003.09.090. Biomaterials. 2004. PMID: 14967528
-
The effect of implant shape and screw pitch on microdamage in mandibular bone.Clin Implant Dent Relat Res. 2015 Apr;17(2):365-72. doi: 10.1111/cid.12100. Epub 2013 Jun 13. Clin Implant Dent Relat Res. 2015. PMID: 23763648 Clinical Trial.
-
Bone-implant interface around titanium implants under different loading conditions: a histomorphometrical analysis in the Macaca fascicularis monkey.J Periodontol. 2003 Oct;74(10):1483-90. doi: 10.1902/jop.2003.74.10.1483. J Periodontol. 2003. PMID: 14653395
Cited by
-
Nanocrystalline hydroxyapatite for bone repair: an animal study.J Mater Sci Mater Med. 2010 Jan;21(1):283-94. doi: 10.1007/s10856-009-3859-1. J Mater Sci Mater Med. 2010. PMID: 19885643
-
Effects of Intrabony Length and Cortical Bone Density on the Primary Stability of Orthodontic Miniscrews.Materials (Basel). 2020 Dec 9;13(24):5615. doi: 10.3390/ma13245615. Materials (Basel). 2020. PMID: 33317089 Free PMC article.
-
Microdamage generation by tapered and cylindrical mini-screw implants after pilot drilling.Angle Orthod. 2015 Sep;85(5):859-67. doi: 10.2319/062314-452.1. Epub 2014 Dec 3. Angle Orthod. 2015. PMID: 25469670 Free PMC article.
-
Repair of microdamage in osteonal cortical bone adjacent to bone screw.PLoS One. 2014 Feb 20;9(2):e89343. doi: 10.1371/journal.pone.0089343. eCollection 2014. PLoS One. 2014. PMID: 24586702 Free PMC article.
-
In vitro and in vivo mechanical stability of orthodontic mini-implants.Angle Orthod. 2012 Jul;82(4):611-7. doi: 10.2319/071311-447.1. Epub 2011 Oct 19. Angle Orthod. 2012. PMID: 22011094 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials