Temperature elevation caused by bone cement polymerization during vertebroplasty
- PMID: 10458268
- DOI: 10.1016/s8756-3282(99)00127-1
Temperature elevation caused by bone cement polymerization during vertebroplasty
Abstract
Percutaneous vertebroplasty (PVP), whereby polymethylmethacrylate cement is injected into the vertebral body (VB), has been used to successfully treat various spinal lesions. The mechanism responsible for the palliative effect of PVP is unknown, but it may be the result of neural damage caused by heat liberated during polymerization of the polymethylmethacrylate. The purpose of the current study was to measure in vitro temperature histories at three key locations (anterior cortex, center, spinal canal) in VBs injected with one of two different bone cements (Simplex P and Orthocomp) to determine the role temperature plays in PVP. Twelve VBs (T11-L2) from three elderly female spines were instrumented with thermocouples and injected with 10 cc of one of the two cements. Temperatures were measured with the VBs in a bath (37 degrees C) for 15 min after injection. A Student's paired t-test was used to determine differences in peak temperature and time above 50 degrees C between the two cement groups. Peak temperatures and temperatures above 50 degrees C were significantly higher and longer, respectively, at the center of VBs injected with Simplex P (61.8 +/- 12.7 degrees C; 3.6 +/- 2.1 min) than those injected with Orthocomp (51.2 +/- 6.2 degrees C; 1.3 +/- 1.4 min). There was no significant difference in peak temperature between cements at the spinal canal location; temperature there did not rise above 41 degrees C. Although thermal damage to intraosseous neural tissue caused by cement polymerization cannot be ruled out as a potential mechanism for pain relief experienced by patients subsequent to PVP, it seems unlikely based on the worst-case conditions tested in the current study.
Similar articles
-
Cement leakage causes potential thermal injury in vertebroplasty.BMC Musculoskelet Disord. 2011 May 26;12:116. doi: 10.1186/1471-2474-12-116. BMC Musculoskelet Disord. 2011. PMID: 21615939 Free PMC article.
-
Radiographic and histologic findings of vertebral augmentation using polymethylmethacrylate in the primate spine: percutaneous vertebroplasty versus kyphoplasty.Spine (Phila Pa 1976). 2006 Jan 1;31(1):E4-10. doi: 10.1097/01.brs.0000192637.60821.ef. Spine (Phila Pa 1976). 2006. PMID: 16395165
-
Temperature measurement during polymerization of bone cement in percutaneous vertebroplasty: an in vivo study in humans.Cardiovasc Intervent Radiol. 2009 May;32(3):491-8. doi: 10.1007/s00270-009-9509-7. Epub 2009 Mar 12. Cardiovasc Intervent Radiol. 2009. PMID: 19280257
-
Chemical and physical properties of bone cement for vertebroplasty.Biomed J. 2013 Jul-Aug;36(4):162-7. doi: 10.4103/2319-4170.112750. Biomed J. 2013. PMID: 23989310 Review.
-
Intradural cement leakage: a devastatingly rare complication of vertebroplasty.Spine (Phila Pa 1976). 2006 May 20;31(12):E379-82. doi: 10.1097/01.brs.0000219495.57470.67. Spine (Phila Pa 1976). 2006. PMID: 16721284 Review.
Cited by
-
Biomechanical Study of 3 Osteoconductive Materials Applied in Pedicle Augmentation and Revision for Osteoporotic Vertebrae: Allograft Bone Particles, Calcium Phosphate Cement, Demineralized Bone Matrix.Neurospine. 2023 Dec;20(4):1407-1420. doi: 10.14245/ns.2346760.380. Epub 2023 Dec 31. Neurospine. 2023. PMID: 38171307 Free PMC article.
-
Percutaneous cementoplasty.Semin Intervent Radiol. 2010 Jun;27(2):137-47. doi: 10.1055/s-0030-1253512. Semin Intervent Radiol. 2010. PMID: 21629403 Free PMC article.
-
Effect of glenoid perforation during total shoulder arthroplasty on glenoid component cement fixation and suprascapular nerve.Shoulder Elbow. 2021 Jun;13(3):276-282. doi: 10.1177/1758573219897040. Epub 2020 Jan 13. Shoulder Elbow. 2021. PMID: 34659467 Free PMC article.
-
Effectiveness of mechanical cleaning, antibiotics, and induction heating on eradication of Staphylococcus aureus in mature biofilms.Bone Joint Res. 2022 Sep;11(9):629-638. doi: 10.1302/2046-3758.119.BJR-2022-0010.R1. Bone Joint Res. 2022. PMID: 36047617 Free PMC article.
-
[Balloon kyphoplasty of vertebral compression fractures with a new calcium phosphate cement].Orthopade. 2004 Jan;33(1):31-9. doi: 10.1007/s00132-003-0578-z. Orthopade. 2004. PMID: 14747908 German.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical