An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty
- PMID: 10458269
- DOI: 10.1016/s8756-3282(99)00128-3
An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty
Abstract
The purpose of this study was to determine the strength and stiffness of osteoporotic vertebral bodies (VBs) subjected to compression fractures and subsequently treated with bipedicular injections of various polymethylmethacrylate cements. Ten spines were harvested from nonembalmed female cadavers (age 68.6 +/- 13.7 years) and evaluated for bone mineral density using the dual energy X-ray absorptiometry method (t-score = -2.3 +/- 2.4). The 50 VBs (L1-L5) were disarticulated, compressed in a materials testing machine to determine initial strength and stiffness, and then assigned to one of six groups. Two of these groups (n = 8, n = 9) concerned experimental cements, the results of which are not reported here. The 33 vertebral bodies in the remaining four groups were left untreated or were repaired using a transpedicular injection of one of three commercially available polymethylmethacrylate cements. These four groups were: a) no treatment (no cement, n = 8); b) Simplex P (n = 9); c) Cranioplastic (n = 8); and d) Osteobond (n = 8). The VBs were then compressed again according to the initial protocol, and posttreatment strength and stiffness were measured. Results suggested that bipedicular injection of Simplex P and Osteobond restored VB stiffness to initial values, whereas VBs injected with Cranioplastic were significantly less stiff than in their initial state. VBs injected with cement (regardless of type) were significantly stronger than they were initially.
Similar articles
-
Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures.Spine (Phila Pa 1976). 1999 Sep 1;24(17):1772-6. doi: 10.1097/00007632-199909010-00004. Spine (Phila Pa 1976). 1999. PMID: 10488505
-
Ex vivo biomechanical comparison of hydroxyapatite and polymethylmethacrylate cements for use with vertebroplasty.AJNR Am J Neuroradiol. 2002 Nov-Dec;23(10):1647-51. AJNR Am J Neuroradiol. 2002. PMID: 12427616 Free PMC article.
-
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty.Spine (Phila Pa 1976). 2001 Jul 15;26(14):1542-6. doi: 10.1097/00007632-200107150-00008. Spine (Phila Pa 1976). 2001. PMID: 11462083
-
Biomechanical evaluation of a new bone cement for use in vertebroplasty.Spine (Phila Pa 1976). 2000 May 1;25(9):1061-4. doi: 10.1097/00007632-200005010-00004. Spine (Phila Pa 1976). 2000. PMID: 10788848
-
Overview of osteoporosis: pathophysiology and determinants of bone strength.Eur Spine J. 2003 Oct;12 Suppl 2(Suppl 2):S90-6. doi: 10.1007/s00586-003-0603-2. Epub 2003 Sep 12. Eur Spine J. 2003. PMID: 13680312 Free PMC article. Review.
Cited by
-
Vertebral body fracture following stand-alone lateral lumbar interbody fusion (LLIF): report of two events out of 712 levels.Eur Spine J. 2015 Apr;24 Suppl 3:409-13. doi: 10.1007/s00586-015-3845-x. Epub 2015 Mar 17. Eur Spine J. 2015. PMID: 25777536
-
A 20-Year Review of Biomechanical Experimental Studies on Spine Implants Used for Percutaneous Surgical Repair of Vertebral Compression Fractures.Biomed Res Int. 2022 Sep 21;2022:6015067. doi: 10.1155/2022/6015067. eCollection 2022. Biomed Res Int. 2022. PMID: 36187502 Free PMC article. Review.
-
Effects of cement augmentation on the mechanical stability of multilevel spine after vertebral compression fracture.J Spine Surg. 2016 Jun;2(2):111-21. doi: 10.21037/jss.2016.06.05. J Spine Surg. 2016. PMID: 27683707 Free PMC article.
-
Percutaneous vertebroplasty: a developing standard of care for vertebral compression fractures.AJNR Am J Neuroradiol. 2001 Feb;22(2):373-81. AJNR Am J Neuroradiol. 2001. PMID: 11156786 Free PMC article. Review. No abstract available.
-
Augmentation of failed human vertebrae with critical un-contained lytic defect restores their structural competence under functional loading: An experimental study.Clin Biomech (Bristol). 2015 Jul;30(6):608-16. doi: 10.1016/j.clinbiomech.2015.03.024. Epub 2015 Mar 28. Clin Biomech (Bristol). 2015. PMID: 25912639 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical