Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Aug;13(6):414-7.
doi: 10.1097/00005131-199908000-00004.

Intraoperative fluoroscopy to evaluate fracture reduction and hardware placement during acetabular surgery

Affiliations

Intraoperative fluoroscopy to evaluate fracture reduction and hardware placement during acetabular surgery

B L Norris et al. J Orthop Trauma. 1999 Aug.

Abstract

Objectives: To evaluate use of intraoperative fluoroscopy during acetabular surgery to determine fracture reduction and accurate placement of screws.

Design: Retrospective.

Setting: Level I trauma center.

Participants: Thirty patients with thirty-two acetabular fractures.

Intervention: Patients were evaluated with fluoroscopy during surgery to assess fracture reduction and screw placement. Anterior-posterior (AP), oblique, and lateral pelvic fluoroscopic images were obtained intraoperatively. Postoperative radiographs were used to verify fluoroscopic findings; computed tomography (CT) scans were used as the control to assess intraarticular screw placement.

Main outcome measurements: Radiographic and clinical assessment of fracture reduction and screw placement.

Results: Intraoperative fluoroscopy confirmed the extra-articular position of all screws evaluated. Postoperative CT scans confirmed the extra-articular placement of all screws assessed by fluoroscopy. Quality of reduction using intraoperative fluoroscopic images had a 100 percent correlation with reduction on final radiographs. One patient, with two screws placed without fluoroscopic evaluation, had intra-articular placement requiring revision surgery.

Conclusions: Intraoperative fluoroscopy is effective in evaluating both acetabular fracture reduction and hardware placement.

PubMed Disclaimer

Comment in

  • Intraoperative fluoroscopy.
    Matta J. Matta J. J Orthop Trauma. 2000 Mar-Apr;14(3):225. doi: 10.1097/00005131-200003000-00021. J Orthop Trauma. 2000. PMID: 10791678 No abstract available.

Similar articles

Cited by

Publication types

LinkOut - more resources