Adaptive template filtering for signal-to-noise ratio enhancement in magnetic resonance imaging
- PMID: 10463132
- DOI: 10.1109/42.781019
Adaptive template filtering for signal-to-noise ratio enhancement in magnetic resonance imaging
Abstract
In this paper, a local shape-adaptive template filtering is proposed for the enhancement of the signal-to-noise ratio (SNR) without the loss of resolution in magnetic resonance (MR) imaging. Unlike conventional filtering, where the template shape and coefficients are fixed, multiple templates are defined in the proposed algorithm. An optimal template is selected and optimal filtering, based on the template, is applied on a pixel-by-pixel basis. Using the proposed process, edge blurring is minimized and SNR enhancement is maximized by selecting the optimally matched template. Compared to existing two-dimensional (2-D) adaptive linear least square error (LLSE) filters or direction-adaptive recursive filters, the proposed adaptive template filter provides higher SNR and sharper edges for both MR and artificial resolution phantom images.
Similar articles
-
Real-time adaptive filtering for projection reconstruction MR fluoroscopy.IEEE Trans Med Imaging. 2003 Jan;22(1):75-81. doi: 10.1109/TMI.2002.806584. IEEE Trans Med Imaging. 2003. PMID: 12703761
-
Adaptive averaging for improved SNR in real-time coronary artery MRI.IEEE Trans Med Imaging. 2004 Aug;23(8):1034-45. doi: 10.1109/TMI.2004.828677. IEEE Trans Med Imaging. 2004. PMID: 15338736 Clinical Trial.
-
Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.J Magn Reson Imaging. 2007 Aug;26(2):375-85. doi: 10.1002/jmri.20969. J Magn Reson Imaging. 2007. PMID: 17622966
-
Adaptive filtering in biological signal processing.Crit Rev Biomed Eng. 1990;17(6):531-84. Crit Rev Biomed Eng. 1990. PMID: 2180633 Review.
-
Data distributions in magnetic resonance images: a review.Phys Med. 2014 Nov;30(7):725-41. doi: 10.1016/j.ejmp.2014.05.002. Epub 2014 Jul 22. Phys Med. 2014. PMID: 25059432 Review.
Cited by
-
An Anthropomorphic Digital Reference Object (DRO) for Simulation and Analysis of Breast DCE MRI Techniques.Tomography. 2022 Apr 2;8(2):1005-1023. doi: 10.3390/tomography8020081. Tomography. 2022. PMID: 35448715 Free PMC article.
-
Gaussian smoothing and modified histogram normalization methods to improve neural-biomarker interpretations for dyslexia classification mechanism.PLoS One. 2021 Feb 25;16(2):e0245579. doi: 10.1371/journal.pone.0245579. eCollection 2021. PLoS One. 2021. PMID: 33630876 Free PMC article.
-
Restoration of DWI data using a Rician LMMSE estimator.IEEE Trans Med Imaging. 2008 Oct;27(10):1389-403. doi: 10.1109/TMI.2008.920609. IEEE Trans Med Imaging. 2008. PMID: 18815091 Free PMC article.
-
Image filtering via generalized scale.Med Image Anal. 2008 Apr;12(2):87-98. doi: 10.1016/j.media.2007.07.007. Epub 2007 Aug 9. Med Image Anal. 2008. PMID: 17827051 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical