. 1999 May;56(5):328-33.
doi: 10.1136/oem.56.5.328.

Two year follow up of pulmonary function values among welders in New Zealand

Affiliations

Two year follow up of pulmonary function values among welders in New Zealand

R Erkinjuntti-Pekkanen et al. Occup Environ Med. 1999 May.

Abstract

Objectives: To examine whether welding is a risk factor for an accelerated decline in pulmonary function.

Methods: 2 Year follow up of pulmonary function and respiratory symptoms among 54 welders and 38 non-welders in eight New Zealand welding sites.

Results: There were no significant differences in age, height, smoking habits, ethnicity, or total time in industrial work between welders and non-welders. No overall differences were noted in the changes of pulmonary function variables between the two study groups. However, when the comparison was restricted to smokers, welders had a significantly greater (p = 0.02) annual decline (88.8 ml) in FEV1 than non-welders, who had a slight non-significant annual increase (34.2 ml). Also, welders without respiratory protection or local exhaust ventilation while welding had a greater annual decline both in forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) than welders with protection (p = 0.001 and 0.04, respectively). Among welders a significant association was found between the acute across shift change and the annual decline in FEV1. Chronic bronchitis was more common among welders (24%) than non-welders (5%). Only one welder (2%) but eight non-welders (21%) reported having asthma.

Conclusions: Welders who smoked and welders working without local exhaust ventilation or respiratory protection have an increased risk of accelerated decline in FEV1.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Chest. 1985 Oct;88(4):608-17 - PubMed
    1. J Soc Occup Med. 1984 Feb;34(1):3-23 - PubMed
    1. Int Arch Occup Environ Health. 1985;56(2):111-7 - PubMed
    1. Am Ind Hyg Assoc J. 1987 Jul;48(7):639-45 - PubMed
    1. Br J Ind Med. 1989 May;46(5):292-301 - PubMed

Publication types