Comparative Study
. 1999 Aug;20(7):1207-13.

Assessment of internal auditory canal tumors: a comparison of contrast-enhanced T1-weighted and steady-state T2-weighted gradient-echo MR imaging

Affiliations
Comparative Study

Assessment of internal auditory canal tumors: a comparison of contrast-enhanced T1-weighted and steady-state T2-weighted gradient-echo MR imaging

P Schmalbrock et al. AJNR Am J Neuroradiol. 1999 Aug.

Abstract

Background and purpose: Although contrast-enhanced T1-weighted MR imaging is the standard of reference for diagnosing tumor in the cerebellopontine angle, high-resolution T2-weighted imaging may show more details of the seventh and eighth cranial nerve branches, resulting in more accurate tumor volume measurements. The purpose of this study was to compare two MR sequences for their ability to delineate internal auditory canal tumors.

Methods: Twenty-seven ears in 21 patients with 16 confirmed schwannomas were studied with the 3D T2-weighted prototype segment-interleaved motion-compensated acquisition in steady state (SIMCAST) and the T1-weighted contrast-enhanced spoiled gradient-echo (SPGR) techniques. Twenty-eight axial sections were acquired using parameters of 17/3.3 (TR/TE), a 40 degrees flip angle, a 20 x 15-cm or 22 x 16-cm field of view (FOV), a 512 x 256 matrix, and a 0.4- or 1.2-mm section thickness for the SIMCAST technique, and 30/4.2, a 30 degrees flip angle, a 20 x 20-cm FOV, a 512 x 288 matrix, and a 1.5-mm section thickness for the SPGR technique. Tumor appearance and depiction of surrounding anatomy, including the cranial nerves, were evaluated. Tumor volumes were measured by manual tracing.

Results: Both sequences clearly identified tumors that ranged in size from 0.06 to 3.0 cm3. Measurements on both sequences agreed, on average, within 14%. The information from both sequences was complementary. SIMCAST usually delineated the CSF spaces better, whereas SPGR more clearly showed the tumor/brain boundary.

Conclusion: SIMCAST and SPGR are suitable for tumor detection and volume measurements. SPGR has somewhat better contrast, but SIMCAST excels at depicting the surrounding anatomy and tumor involvement of the seventh and eighth cranial nerves.

PubMed Disclaimer

Figures

<sc>fig</sc> 1.
fig 1.
Case 19: Slightly oblique axial reformatted images of a small mass. A, SIMCAST image acquired in 5:05 minutes with parameters of 12.3/2.3, 40° flip angle, 22 × 16-cm FOV, 512 × 256 matrix, 32-kHz receiver bandwidth, four RF phase stepping loops , and 32 0.8-mm-thick sections interpolated to 0.4 mm. B, Contrast-enhanced study acquired in 4:07 minutes with parameters of 40/4.2/1, 30° flip angle, identical FOV and matrix size, 15.6-kHz receiver bandwidth, and 32 1.6-mm-thick sections interpolated to 0.8 mm. Both images (A and B) depict the superior portion of the IAC. On the SIMCAST image (A), a continuous dark line extending from the brain stem to the fundus of the IAC is seen in the anterior portion of the IAC, presumably the facial nerve (solid arrows). Only a portion of the facial nerve is seen on the T1-weighted image (B). With SIMCAST, the tumor mass (open arrow) is clearly seen in the posterior portion of the IAC, displacing the facial nerve anteriorly and leading to a tortuous course around the tumor. Tumor volumes of 0.082 cm3 and 0.078 cm3 were measured on the SIMCAST and T1-weighted images, respectively. The tumor size is 6 mm along the IAC with both sequences, but may appear slightly wider across the IAC on the T1-weighted image than on the SIMCAST image, possibly due to partial volume effects or to tumor involvement of the nerve, leading to signal enhancement. Note that small vessels (dashed arrows) have low signal on the SIMCAST image and high signal on the T1-weighted images, due to the presence of contrast agent in the vessels. With the SIMCAST sequence, using zero-order motion-compensated gradients over TR, no signal loss is observed with slow motion, such as is present in CSF or in the IAC (v < 0.6 cm/s; phantom study by Schmalbrock P, presented at the International Society for Magnetic Resonance in Medicine, 1998). Higher-order motion components are present for faster vascular flow and result in dephasing and signal decrease, accounting for the low vascular signal.
<sc>fig</sc> 2.
fig 2.
Case 11. A and B, Reformatted axial (A) and coronal (B) SIMCAST images acquired in 5:05 minutes with parameters of 12.3/2.3, 40° flip angle, 22 × 16-cm FOV, 512 × 256 matrix, 32-kHz receiver bandwidth, four RF phase stepping loops , and 32 0.8-mm-thick axial sections interpolated to 0.4 mm. A was magnified by a factor of three from the original data and reformatted along an axially oriented curved surface from the brain stem to the superior portion of the IAC containing the facial nerve (fn). Only a portion of the superior vestibular nerve (svn) is seen in this view. B was magnified sixfold and reformatted along a coronally oriented curved surface following the facial nerve in the anterior portion of the IAC. Other labeled structures include the pons (pons), the pontomedullary junction (pmj), and the superior aspect of the porus acousticus (spa). The curved views permit continuous depiction of the facial nerve from the brain stem to the fundus of the IAC. On the curved axial image (A) the facial nerve is pushed anteriorly by the tumor (open arrow). On the curved coronal image (B), the nerve courses superiorly to the tumor. There is remodeling of the IAC. In this patient, surgery preserved hearing.
<sc>fig</sc> 3.
fig 3.
Case 10: IAC mass (right side) with a tumor volume of 0.6 cm3. A–D, On SIMCAST images (A and C), acquired in 5:05 minutes with parameters of 12.3/2.3, 40° flip angle, 22 × 16-cm FOV, 512 × 256 matrix, 32-kHz receiver bandwidth, four RF phase stepping loops , and 32 0.8-mm-thick sections interpolated to 0.4 mm, the tumor is isointense with brain tissue; nevertheless its boundary may be estimated by using vascular structures (arrows) as reference points. On contrast-enhanced images (B and D), acquired in 5:20 minutes with parameters of 30/4.2/1, 30° flip angle, 20 × 20-cm FOV, 512 × 288 matrix, 15.6-kHz receiver bandwidth, and 60 1.5-mm-thick sections, the hyperintense tumor is easily distinguishable from the adjacent flocculus (fl) and cerebral peduncle.

References

    1. Weissman J. Hearing loss. Radiology 1996;199:593-611 - PubMed
    1. Chakeres DW, Oehler M, Schmalbrock P, Slone W. Temporal bone imaging. In: Som PM, Curtain HD, eds. Head and Neck Imaging St Louis: Mosby; 1996;1319-1350
    1. Stone JA, Chakeres DW, Schmalbrock P. High resolution imaging of the auditory pathway. MR Clin North Am 1998;6:195-217 - PubMed
    1. Lee JN, King BD, Parker DL, Buswell HR. High resolution 3D imaging of the inner ear with a modified fast spin-echo pulse sequence. J Magn Reson Imaging 1996;6:223-225 - PubMed
    1. Casselman JW, Kuhweide R, Deimling M, Ampe W, Dehaene I, Meeus L. Constructive interference in steady-state-3DFT MR imaging of the inner ear and cerebellopontine angle. AJNR Am J Neuroradiol 1993;14:47-57 - PMC - PubMed

Publication types