Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Sep;12(9):720-8.
doi: 10.1016/s0894-7317(99)70022-2.

Coronary flow reserve of normal left anterior descending artery in patients with ischemic heart disease: A transesophageal Doppler study

Affiliations

Coronary flow reserve of normal left anterior descending artery in patients with ischemic heart disease: A transesophageal Doppler study

C Coletta et al. J Am Soc Echocardiogr. 1999 Sep.

Abstract

The aim of this study was to investigate the flow reserve of a normal left anterior descending coronary artery (LAD) in patients with coronary artery disease (CAD) of other epicardial vessels by Doppler transesophageal echocardiography (TEE). Thirty-one consecutive patients (age 59 +/- 8 years; 23 men) referred for TEE were considered. Eighteen patients had CAD and a 70% or greater LAD stenosis (group 1); 13 patients had right and/or circumflex CAD (>/=70% stenosis) and normal or minimally diseased LAD (group 2). Ten patients (age 54 +/- 11 years) with normal coronary arteries constituted group 3. Baseline and adenosine (0.160 microg/kg per minute intravenously over 60 minutes) flow velocities in the LAD were measured by pulsed Doppler examination during TEE. Peak and mean systolic and diastolic flow velocities were calculated. Adenosine/baseline peak and mean velocity ratios were used for evaluating blood flow reserve in the LAD. Heart rate and arterial pressure values were similar in the 3 groups at baseline and during adenosine infusion. Baseline and adenosine-related flow velocities were comparable in the 3 groups. Peak and mean diastolic velocity ratios were lower in groups 1 and 2 compared with group 3 (peak velocity ratio 1.68 +/- 0.81 and 1.93 +/- 0.35 vs 2.62 +/- 0.32, P <. 05; mean velocity ratio 1.71 +/- 0.86 and 2.01 +/- 0.41 vs 2.84 +/- 0.74, P <.05), whereas no differences were found between groups 1 and 2. No significant differences were found in systolic flow velocity ratios among the 3 groups. Patients with ischemic heart disease have a reduced diastolic flow velocity reserve in the LAD independent from the presence of significant LAD stenosis. Thus the adenosine TEE-Doppler study should be considered a screening test for CAD rather than for LAD disease.

PubMed Disclaimer

LinkOut - more resources