Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Jul;128(1):38-44.
doi: 10.1016/s0002-9394(99)00071-9.

The VF-14 index of functional visual impairment in candidates for a corneal graft

Affiliations

The VF-14 index of functional visual impairment in candidates for a corneal graft

H Boisjoly et al. Am J Ophthalmol. 1999 Jul.

Abstract

Purpose: To validate the Visual Function-14 (VF-14) index of functional visual impairment in candidates for a corneal graft.

Methods: One hundred thirty-four patients who were candidates for a corneal graft participated in this study between August 1996 and February 1997. Demographic, ocular history, best-corrected visual acuity, and detailed ocular examination data were collected. Functional visual impairment information was obtained by telephone interviews using the following: VF-14, SF-36 (Short Form-36, a more generic measure of general health function), and Visual Symptom Score, and four questions measuring the overall amount of trouble with vision, dissatisfaction with vision, ocular pain, and discomfort.

Results: The average age of corneal graft candidates was 64 +/- 18 years (range, 18 to 90 years) and 60% were women. The most frequent corneal disease was pseudophakic bullous keratopathy (41%). Ocular comorbidities included glaucoma or ocular hypertension (30%) and cataract (19%). The mean best-corrected visual acuity of the eye scheduled for surgery was 1.33 +/- 0.56 logMAR whereas the best eye best-corrected visual acuity was 0.36 +/- 0.44 logMAR. The mean VF-14 score was 73% +/- 26%, and the internal consistency was high, with a Cronbach alpha value of 0.94. The VF-14 correlated strongly with the best eye best-corrected visual acuity. It also correlated strongly with the Visual Symptom Score, the global measures of trouble and dissatisfaction with vision. Candidates for a corneal graft had low scores for all eight general health concepts evaluated with the SF-36, and the VF-14 correlated with seven of the eight SF-36 subscales.

Conclusion: The VF-14 is a valid measure of functional visual impairment in candidates for a corneal graft. The Visual Symptom Score and the SF-36 are also useful indices in such patients.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources