Isotope dilution-gas chromatography/mass spectrometry (ID-GC/MS) and isotope dilution-liquid chromatography/tandem mass spectrometry (ID-LC/MS/MS) methods have been developed for an determination of triiodothyronine (T3) in serum and their potential as candidate reference methods investigated. In both methods, (13)C(9)-T3 was used as internal standard. Sample pretreatment consisted of deproteinization, extraction and high performance liquid chromatography (HPLC) purification. Conversion of serum thyroxine (T4) to T3 was controlled by adding (13)C(6)-T4. For GC/MS, T3 and (13)C(9)-T3 were converted to the N,O-di-heptafluorobutyryl (HFB) methyl ester derivatives and monitored at m/z 844 and 853. For LC/MS with electrospray ionization, the transitions m/z 652/661 to 606/614 were monitored. For use of the methods as candidate reference methods, special attention was paid to the calibration and the measurement protocol (duplicate analysis of each sample on three occasions). Evaluation of the ID-GC/MS and ID-LC/MS/MS methods showed the absence of interference by reverse T3 and T4, a limit of detection of 100 pg (GC/MS) and 18 pg (LC/MS), a recovery of 100 +/- 1.5% (95% confidence interval) and good precision (the total coefficient of variation, n = 6, was typically 1.5%). In addition to the recovery study, the accuracy of the methods was proven by method comparison (ID-GC/MS vs. LC/MS/MS) on three sera, showing a maximum deviation of 1.1%. Finally, the ID-GC/MS method was applied for measurement of 10 different human sera with a T3 concentration range from 0.6 to 7.3 ng/mL.
Copyright 1999 John Wiley & Sons, Ltd.
Similar articles
-
Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method.J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Oct 1;857(2):287-95. doi: 10.1016/j.jchromb.2007.07.035. Epub 2007 Aug 2. J Chromatogr B Analyt Technol Biomed Life Sci. 2007. PMID: 17704012
-
Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry.Anal Chem. 2004 Feb 15;76(4):1008-14. doi: 10.1021/ac034966f. Anal Chem. 2004. PMID: 14961732
-
Isotope dilution-liquid chromatography/electrospray ionization-tandem mass spectrometry for the determination of serum thyroxine as a potential reference method.Rapid Commun Mass Spectrom. 1998;12(16):1099-103. doi: 10.1002/(SICI)1097-0231(19980831)12:16<1099::AID-RCM290>3.0.CO;2-J. Rapid Commun Mass Spectrom. 1998. PMID: 9737016
-
Residue analysis of 500 high priority pesticides: better by GC-MS or LC-MS/MS?Mass Spectrom Rev. 2006 Nov-Dec;25(6):838-65. doi: 10.1002/mas.20091. Mass Spectrom Rev. 2006. PMID: 16755599 Review.
-
Isotope dilution mass spectrometry: definitive methods and reference materials in clinical chemistry.Ann Ist Super Sanita. 1991;27(3):401-10. Ann Ist Super Sanita. 1991. PMID: 1809059 Review.
Cited by
-
Thyroid hormone testing by tandem mass spectrometry.Clin Biochem. 2011 Jan;44(1):89-94. doi: 10.1016/j.clinbiochem.2010.07.020. Epub 2010 Aug 4. Clin Biochem. 2011. PMID: 20691174 Free PMC article. Review.
-
Development and validation of an isotope dilution-liquid chromatography (ID-LC-MS/MS)-based candidate reference measurement procedure for total 3,3',5-triiodothyronine in human serum.Anal Bioanal Chem. 2025 May;417(13):2923-2933. doi: 10.1007/s00216-025-05834-y. Epub 2025 Mar 22. Anal Bioanal Chem. 2025. PMID: 40119927
-
Determination of Thyroid Hormones and 11 Metabolites in the Human Serum Using a Simple Derivatization Strategy and Analysis by Isotope-Dilution Liquid Chromatography Tandem Mass Spectrometry.Anal Chem. 2025 May 6;97(17):9438-9446. doi: 10.1021/acs.analchem.5c00714. Epub 2025 Apr 23. Anal Chem. 2025. PMID: 40267502 Free PMC article.
-
Simultaneous quantification of T4, T3, rT3, 3,5-T2 and 3,3'-T2 in larval zebrafish (Danio rerio) as a model to study exposure to polychlorinated biphenyls.Biomed Chromatogr. 2018 Jun;32(6):e4185. doi: 10.1002/bmc.4185. Epub 2018 Jan 29. Biomed Chromatogr. 2018. PMID: 29314156 Free PMC article.
-
Isotope dilution tandem mass spectrometric method for T4/T3.Clin Chim Acta. 2004 May;343(1-2):185-90. doi: 10.1016/j.cccn.2004.01.007. Clin Chim Acta. 2004. PMID: 15115693 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials
Miscellaneous