Volume-rendered three-dimensional spiral CT: musculoskeletal applications
- PMID: 10489170
- DOI: 10.1148/radiographics.19.5.g99se061143
Volume-rendered three-dimensional spiral CT: musculoskeletal applications
Abstract
Spiral computed tomography (CT) is a powerful modality for evaluation of the musculoskeletal system, particularly when coupled with real-time, volume-rendering reconstruction techniques. Including volume-rendered spiral CT in routine musculoskeletal imaging protocols can change management in a significant number of cases. In cases of trauma, subtle fractures--particularly those oriented in the axial plane--are better seen on volume-rendered images. Complex injuries can be better demonstrated with volume-rendered images, and complicated spatial information about the relative positions of fracture fragments can be easily demonstrated to the orthopedic surgeons. The use of intravenously administered contrast material allows simultaneous evaluation of osseous and vascular structures within the affected area. Evaluation of suspected infectious or neoplastic disease is also aided by including volume-rendered imaging in the musculoskeletal spiral CT examination. The extent of disease can be thoroughly evaluated with volume-rendered images, and therapeutic planning--be it surgical or medical--is aided by the anatomic information available from volume-rendered images. Postoperative studies in patients with orthopedic hardware also benefit from volume-rendered imaging. Volume rendering eliminates most streak artifact and produces high-quality images on which the relationships among hardware, bones, and bone fragments are well demonstrated.
Similar articles
-
CT of pelvic fractures.Eur J Radiol. 2004 Apr;50(1):96-105. doi: 10.1016/j.ejrad.2003.11.019. Eur J Radiol. 2004. PMID: 15093240 Review.
-
CT and MRI evaluation of musculoskeletal infection.Crit Rev Diagn Imaging. 1997 Dec;38(6):535-68. Crit Rev Diagn Imaging. 1997. PMID: 9442978 Review.
-
Comparative study of different intraoperative 3-D image intensifiers in orthopedic trauma care.J Trauma. 2009 Mar;66(3):821-30. doi: 10.1097/TA.0b013e31815edf34. J Trauma. 2009. PMID: 19276760
-
Imaging of musculoskeletal trauma in three dimensions. An integrated two-dimensional/three-dimensional approach with computed tomography.Radiol Clin North Am. 1989 Sep;27(5):945-56. Radiol Clin North Am. 1989. PMID: 2570440
-
Musculoskeletal applications for computed tomography.Bull Rheum Dis. 1983;33(3):1-4. Bull Rheum Dis. 1983. PMID: 6225479 Review. No abstract available.
Cited by
-
Multidetector CT and three-dimensional CT angiography of upper extremity arterial injury.Emerg Radiol. 2015 Jun;22(3):269-82. doi: 10.1007/s10140-014-1288-z. Epub 2014 Dec 11. Emerg Radiol. 2015. PMID: 25504031
-
Computed Tomography in Limb Salvage and Deformity Correction-3D Assessment, Indications, Radiation Exposure, and Safety Considerations.J Clin Med. 2021 Aug 24;10(17):3781. doi: 10.3390/jcm10173781. J Clin Med. 2021. PMID: 34501227 Free PMC article.
-
Three-dimensional scanning with dual-source computed tomography in patients with acute skeletal trauma.Clinics (Sao Paulo). 2010;65(10):991-1002. doi: 10.1590/s1807-59322010001000012. Clinics (Sao Paulo). 2010. PMID: 21120300 Free PMC article.
-
Technologies for image distribution in hospitals.Eur Radiol. 2006 Jun;16(6):1270-9. doi: 10.1007/s00330-006-0153-1. Epub 2006 Mar 10. Eur Radiol. 2006. PMID: 16534601
-
Use of 3D imaging in CT of the acute trauma patient: impact of a PACS-based software package.Emerg Radiol. 2005 Apr;11(3):173-6. doi: 10.1007/s10140-004-0384-x. Emerg Radiol. 2005. PMID: 16028324
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical