Comparative analysis of quantification of viral load in patients infected with hepatitis C virus: quantiplex HCV RNA assay and amplicor monitor assay
- PMID: 10491489
Comparative analysis of quantification of viral load in patients infected with hepatitis C virus: quantiplex HCV RNA assay and amplicor monitor assay
Abstract
Objective: two standardized techniques, Quantiplex HCV RNA 2.0 (bDNA) and Amplicor Monitor, were evaluated for the quantification of hepatitis C virus (HCV) load. Our objectives were: 1) to determine the relationship between viral load and genotype, and 2) to evaluate viral load in serial serum samples and in patients with normal or slightly elevated liver enzyme values in an area with a high prevalence of genotype 1.
Results: the viral loads detected with the two methods correlated significantly (r = 0.7, p < 0.0001), but viral load was smaller with the Monitor than with the Quantiplex assay, and was independent of genotype. The Monitor/Quantiplex ratio was lower in patients with a non-1 genotype than in patients with genotype 1b. Virological characteristics were similar in patients with normal or slightly elevated enzyme levels and in patients with elevated enzyme values. Neither method showed a relationship between viral load and age, sex, duration of the infection, mode of transmission, or histological activity index.
Conclusion: viral load was not dependent on genotype. Measurement of viral load in a single serum sample adequately reflected the viral load measured in several serum samples from patients with chronic HCV infection. Patients with normal liver enzyme levels are not good candidates, in virological terms, for treatment with interferon.
Similar articles
-
[Comparative analysis of viral load by bDNA HCV RNA-2.0 and amplicor HCV monitor in patients with hepatitis C infection].Enferm Infecc Microbiol Clin. 2000 Jan;18(1):6-11. Enferm Infecc Microbiol Clin. 2000. PMID: 10721555 Spanish.
-
Effect of genotypes on the quantification of hepatitis C virus (HCV) RNA in clinical samples using the Amplicor HCV Monitor Test and the Quantiplex HCV RNA 2.0 assay (bDNA).J Med Virol. 1998 Jul;55(3):191-6. J Med Virol. 1998. PMID: 9624605
-
Comparison of HCV RNA assays for the detection and quantification of hepatitis C virus RNA levels in serum of patients with chronic hepatitis C treated with interferon.J Med Virol. 1997 May;52(1):105-12. J Med Virol. 1997. PMID: 9131466
-
Association of lipid profiles with hepatitis C viral load in chronic hepatitis C patients with genotype 1 or 2 infection.Am J Gastroenterol. 2009 Mar;104(3):598-604. doi: 10.1038/ajg.2008.125. Epub 2009 Feb 10. Am J Gastroenterol. 2009. PMID: 19262519
-
Branched DNA for quantification of viral load.Immunol Invest. 1997 Jan-Feb;26(1-2):9-13. doi: 10.3109/08820139709048911. Immunol Invest. 1997. PMID: 9037608 Review.