An x-ray computed microtomography system for specimen and small animal imaging was built and tested. The system used seventeen 48-microm-wide detector arrays (a charge coupled device camera) and helical acquisition techniques. Images were acquired using 540 rays/view and 400 views/2pi. The modulation transfer function (MTF) of the computed tomography images demonstrated 50 microm limiting resolution, with MTF > 10% for objects larger than 60 microm (approximately 8.3 cycles/mm). While soft tissue discrimination was compromised by a low signal-to-noise ratio, equine medullary bone core samples and the murine skeleton were well visualized. The incorporation of multiple detector arrays provided a 17-fold improvement in x-ray efficiency, which is a very important step toward improving the potential of microtomography as a scientific tool.
Similar articles
-
Cone-beam x-ray microtomography of small specimens.Phys Med Biol. 1994 Oct;39(10):1639-57. doi: 10.1088/0031-9155/39/10/009. Phys Med Biol. 1994. PMID: 15551536
-
X-ray computed microtomography (microCT) using synchrotron radiation (SR).Prog Biophys Mol Biol. 1996;65(1-2):133-69. doi: 10.1016/s0079-6107(96)00011-9. Prog Biophys Mol Biol. 1996. PMID: 9029944 Review. No abstract available.
-
High-resolution x-ray imaging at soft diagnostic energies using a silicon photodiode array.Med Phys. 1993 Sep-Oct;20(5):1497-504. doi: 10.1118/1.597113. Med Phys. 1993. PMID: 8289734
-
Cone-beam computed tomography with a flat-panel imager: initial performance characterization.Med Phys. 2000 Jun;27(6):1311-23. doi: 10.1118/1.599009. Med Phys. 2000. PMID: 10902561
-
Physics of cardiac imaging with multiple-row detector CT.Radiographics. 2007 Sep-Oct;27(5):1495-509. doi: 10.1148/rg.275075045. Radiographics. 2007. PMID: 17848705 Review.
Cited by
-
High resolution X-ray computed tomography: an emerging tool for small animal cancer research.Neoplasia. 2000 Jan-Apr;2(1-2):62-70. doi: 10.1038/sj.neo.7900069. Neoplasia. 2000. PMID: 10933069 Free PMC article. Review.
-
Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.Med Phys. 2008 Aug;35(8):3728-39. doi: 10.1118/1.2952653. Med Phys. 2008. PMID: 18777932 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous