Abstract
Ischemic colitis is a serious complication of aortic surgery. The condition continues to be difficult to diagnose at an early stage. This study monitors the biochemical changes in systemic and selective inferior mesenteric vein (IMV) blood sampling during aortic surgery and compares the reproducibility of this method to intraoperative colonic pulse oximetry in a series of 18 patients undergoing infrarenal aortic aneurysm repair. Base excess, pH, pCO2, and lactate were altered by aortic cross-clamping but returned to normal within 48 hr. IMV inorganic phosphate levels were higher than systemic values, suggesting improved sensitivity with selective sampling. BB isoenzymes of creatine kinase remained normal in all patients. Pulse oximetry signals were inconsistently obtained from the colon. This study establishes the physiological changes in IMV biochemistry during aortic surgery. Unlike intraoperative pulse oximetry, selective IMV sampling provides reproducible measurements of colonic perfusion. This simple and safe technique warrants further assessment of its accuracy at diagnosing ischemic colitis.
Similar articles
-
Inferior mesenteric venous sampling to detect colonic ischemia: a comparison with laser Doppler flowmetry and photoplethysmography.J Vasc Surg. 1995 Sep;22(3):271-7; discussion 278-9. doi: 10.1016/s0741-5214(95)70141-9. J Vasc Surg. 1995. PMID: 7674470
-
Assessment of gut mucosal perfusion and colonic tissue blood flow during abdominal aortic surgery with gastric tonometry and laser Doppler flowmetry.Vasc Endovascular Surg. 2002 May-Jun;36(3):193-8. doi: 10.1177/153857440203600306. Vasc Endovascular Surg. 2002. PMID: 12075384
-
Endoluminal pulse oximetry combined with tonometry to monitor the perfusion of the sigmoid during and after resection of abdominal aortic aneurysm.Cardiovasc Surg. 1997 Feb;5(1):65-70. doi: 10.1016/s0967-2109(96)00047-6. Cardiovasc Surg. 1997. PMID: 9158125
-
[Behavior of gamma-glutamyl-transpeptidase during chronic respiratory insufficiency].Bronchopneumologie. 1977 Jan-Feb;27(1):35-40. Bronchopneumologie. 1977. PMID: 18261 French. No abstract available.
-
Decreased activity of commonly measured serum enzymes: causes and clinical significance.Am J Med Technol. 1983 Apr;49(4):241-5. Am J Med Technol. 1983. PMID: 6189394 Review.
Cited by
-
Enhanced surgical imaging: laparoscopic vessel identification and assessment of tissue oxygenation.J Am Coll Surg. 2008 Jun;206(6):1159-66. doi: 10.1016/j.jamcollsurg.2008.01.013. J Am Coll Surg. 2008. PMID: 18501814 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical