Assessment of the mechanical properties of coronary arteries using intravascular ultrasound: an in vivo study

Affiliations

Assessment of the mechanical properties of coronary arteries using intravascular ultrasound: an in vivo study

M J Williams et al. Int J Card Imaging. 1999 Aug.

Abstract

The pressure-area relation of coronary arteries provides important information about the mechanical properties of these vessels. In human subjects methodological limitations have precluded measurement of instantaneous compliance and coronary stress in vivo. The purpose of this study was to assess a new method for measuring instantaneous values of coronary artery compliance and wall stress utilizing simultaneously acquired pressure and intravascular ultrasound measurements of vessel area. Ten subjects with coronary artery disease had intravascular ultrasound studies of the proximal left anterior descending or circumflex coronary arteries. Coronary luminal area was measured with a 30-MHz (3F or 3.5F) intravascular ultrasound catheter and simultaneous coronary pressure measured with a 2F micromanometer-tipped catheter. Using this technique the nonlinear pressure-area relation and mean circumferential wall stress were determined over the physiological pressure range. Coronary artery compliance at 100 mmHg ranged from 0.010 to 0.052 mm2/mmHg (mean +/- SD, 0.020+/-0.012 mm2/mmHg). Peak systolic circumferential stress ranged from 0.52 to 2.03 x 10(6) dyn/cm2 (1.09+/-0.42 x 10(6) dyn/cm2). This study describes a new method of determining coronary artery mechanical properties over the physiological pressure range. This technique may be useful in further studies of coronary artery mechanics.

PubMed Disclaimer

References

    1. Int J Cardiol. 1986 Oct;13(1):27-45 - PubMed
    1. J Am Soc Echocardiogr. 1992 Nov-Dec;5(6):577-87 - PubMed
    1. Lancet. 1986 Feb 8;1(8476):307-10 - PubMed
    1. Am J Cardiol. 1997 Jun 15;79(12):1596-600 - PubMed
    1. Eur Heart J. 1990 Nov;11(11):990-6 - PubMed

Publication types

LinkOut - more resources