Smoke alarm installation and function in inner London council housing
- PMID: 10519711
- PMCID: PMC1718123
- DOI: 10.1136/adc.81.5.400
Smoke alarm installation and function in inner London council housing
Abstract
Aim: To determine the prevalence of and predictors for installed, functioning smoke alarms in council (public) housing in a low income, multi-ethnic urban area.
Design: Cross sectional study.
Setting: 40 materially deprived electoral wards in two inner London boroughs.
Participants: Occupants of 315 addresses randomly selected from council housing lists, with 75% response rate.
Main outcome measures: Installation and function of smoke alarms based on inspection and testing.
Results: 39% (95% confidence interval (CI) 33% to 46%) of council tenants owned a smoke alarm, 31% (95% CI 25% to 38%) had an installed alarm (of which 54% were correctly installed), and 16% (95% CI 12% to 22%) had at least one installed, functioning alarm. Alarms most commonly failed because they lacked batteries (72%). In multivariate modelling, having an installed, functioning alarm was most strongly associated with living in a house versus a flat (apartment) (odds ratio (OR) 3.2, 95% CI 1.1 to 10.0), having two resident adults versus one (OR 2.8, 95% CI 1.2 to 6.5), and recognising stills from a Home Office television smoke alarm campaign (OR 2.4, 95% CI 1.1 to 5.5).
Conclusions: Fires are a leading cause of child injury and death, particularly among those younger than 5 years of age and those in social classes IV and V. Smoke alarms are associated with a significantly reduced risk of death in residential fires, and are more protective in households with young children. Few council properties in a multi-ethnic, materially deprived urban area had any installed, functioning smoke alarms, despite a high risk of residential fires and fire related injuries in such areas. Effective methods to increase the prevalence of installed and functioning alarms must be identified.
Similar articles
-
Incidence of fires and related injuries after giving out free smoke alarms: cluster randomised controlled trial.BMJ. 2002 Nov 2;325(7371):995. doi: 10.1136/bmj.325.7371.995. BMJ. 2002. PMID: 12411355 Free PMC article. Clinical Trial.
-
Putting public health evidence into practice: increasing the prevalence of working smoke alarms in disadvantaged inner city housing.J Epidemiol Community Health. 2004 Apr;58(4):280-5. doi: 10.1136/jech.2003.007948. J Epidemiol Community Health. 2004. PMID: 15026437 Free PMC article. Clinical Trial.
-
The "Let's Get Alarmed!" initiative: a smoke alarm giveaway programme.Inj Prev. 1999 Sep;5(3):177-82. doi: 10.1136/ip.5.3.177. Inj Prev. 1999. PMID: 10518263 Free PMC article. Clinical Trial.
-
Disparities in the prevalence of smoke alarms in U.S. households: Conclusions drawn from published case studies.J Safety Res. 2011 Oct;42(5):409-13. doi: 10.1016/j.jsr.2011.10.001. Epub 2011 Oct 19. J Safety Res. 2011. PMID: 22093576 Review.
-
Evaluated community fire safety interventions in the United States: a review of current literature.J Community Health. 2006 Jun;31(3):176-97. doi: 10.1007/s10900-005-9007-z. J Community Health. 2006. PMID: 16830506 Review.
Cited by
-
Prevalence of working smoke alarms in local authority inner city housing: randomised controlled trial.BMJ. 2002 Nov 2;325(7371):998-1001. doi: 10.1136/bmj.325.7371.998. BMJ. 2002. PMID: 12411356 Free PMC article. Clinical Trial.
-
Incidence of fires and related injuries after giving out free smoke alarms: cluster randomised controlled trial.BMJ. 2002 Nov 2;325(7371):995. doi: 10.1136/bmj.325.7371.995. BMJ. 2002. PMID: 12411355 Free PMC article. Clinical Trial.
-
When one is not enough: prevalence and characteristics of homes not adequately protected by smoke alarms.Inj Prev. 2005 Dec;11(6):364-8. doi: 10.1136/ip.2005.009175. Inj Prev. 2005. PMID: 16326772 Free PMC article.
-
Putting public health evidence into practice: increasing the prevalence of working smoke alarms in disadvantaged inner city housing.J Epidemiol Community Health. 2004 Apr;58(4):280-5. doi: 10.1136/jech.2003.007948. J Epidemiol Community Health. 2004. PMID: 15026437 Free PMC article. Clinical Trial.
-
Urban residential fire and flame injuries: a population based study.Inj Prev. 2000 Dec;6(4):250-4. doi: 10.1136/ip.6.4.250. Inj Prev. 2000. PMID: 11144621 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources