[Diagnostic value of signal-enhanced color Doppler ultrasound in space-occupying lesions of the skin and skin appendages]
- PMID: 10520331
- DOI: 10.1055/s-1999-249
[Diagnostic value of signal-enhanced color Doppler ultrasound in space-occupying lesions of the skin and skin appendages]
Abstract
Purpose: Prospective evaluation of the diagnostic outcome of plain and signal-enhanced color Doppler sonography for the differentiation between benign and malignant cutis-involving lesions.
Materials and methods: 39 patients with 40 suspected malignant skin lesions received an preoperative ultrasound examination before and after application of 4 g Levovist i.v. Spectral Doppler, conventional color and power Doppler were performed. The images were analyzed semiquantitatively using a specially developed software. The diagnoses were confirmed by histological analysis (37 cases) or by follow up controls (3 cases).
Results: Whereas the B-mode criteria such as echogenoity, borderline and homogenecity, and the spectral Doppler analysis were not useful for differentiation between malignant and benign lesions, the analysis of the intratumorously visible number of vessels and of the ratio of the vascularized area using a special software, especially after injection of the signal enhancing agent, provided valuable information. In 10 of 18 benign but only in 1 of 22 malignant lesions, no intratumorous vessels were visible after application of Levovist (plain: 10/18 benign and 6/22 malignant lesions). The number of visible vessels increased strongly after signal enhancement. Using a "ratio of the vascularized area (percentage vessel area) > 5%" as a criterion of malignancy, 2 false positive and 2 false negative results were observed after application of Levovist (without/with Levovist sensitivity 73%/91%, specificity 89%/89%).
Conclusions: The signal-enhanced color Doppler sonography provides useful additional information for the differentiation between benign and malignant cutis-involving lesions, especially the semiquantitative vascularization analysis. The latter is superior to B-mode ultrasound and to spectral Doppler analysis. The signal enhancer increases the sensitivity, whereas the specificity remains unchanged.
Similar articles
-
Tumor vascularization in experimental melanomas: correlation between unenhanced and contrast enhanced power Doppler imaging and histological grading.Ultrasound Med Biol. 2001 Jun;27(6):761-71. doi: 10.1016/s0301-5629(01)00363-5. Ultrasound Med Biol. 2001. PMID: 11516536
-
Vascularization of malignant and benign skin tumours measured by D-galactose-based signal-enhanced colour Doppler sonography.Acta Radiol. 2001 May;42(3):294-301. doi: 10.1080/028418501127346855. Acta Radiol. 2001. PMID: 11350288
-
[Prospective analysis of quantification of contrast media enhanced power Doppler sonography of equivocal breast lesions].Rofo. 2003 Apr;175(4):495-501. doi: 10.1055/s-2003-38447. Rofo. 2003. PMID: 12677504 German.
-
Contrast-enhanced three-dimensional power Doppler angiography of the human prostate: correlation with biopsy outcome.Urology. 1999 Jul;54(1):97-104. doi: 10.1016/s0090-4295(99)00040-0. Urology. 1999. PMID: 10414734 Review.
-
Ultrasound and swallowing.Folia Phoniatr Logop. 1999 Jul-Oct;51(4-5):183-98. doi: 10.1159/000021496. Folia Phoniatr Logop. 1999. PMID: 10450025 Review.
Cited by
-
High-frequency ultrasound for diagnosing skin cancer in adults.Cochrane Database Syst Rev. 2018 Dec 4;12(12):CD013188. doi: 10.1002/14651858.CD013188. Cochrane Database Syst Rev. 2018. PMID: 30521683 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical