Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT
- PMID: 10520710
Left ventricular volumes and ejection fraction calculated from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPECT
Abstract
We compared the left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) as calculated by Cedars automated quantitative gated SPECT (QGS) to those determined by first-pass radionuclide angiography (FPRNA) and contrast left ventriculography (LVG) in a group of 21 patients (mean age 61.4 +/- 9.2 y).
Methods: A total of 740 MBq 99mTc-tetrofosmin was administered rapidly into the right cubital vein at rest, and FPRNA was performed using a multicrystal gamma camera. One hour after injection, QGS was performed with a temporal resolution of 10 frames per R-R interval. LVG was performed within 2 wk.
Results: The EDV, ESV and LVEF calculated by QGS were highly reproducible (intraobserver, r = 0.99, r = 0.99 and r = 0.99, respectively; interobserver, r = 0.99, r = 0.99 and r = 0.99, respectively; P < 0.01) and were more consistent than those determined by FPRNA (intraobserver, r = 0.97, r = 0.95 and r = 0.93, respectively; interobserver, r = 0.86, r = 0.96 and r = 0.91, respectively; P < 0.01). There was a good correlation between EDV, ESV and LVEF by FPRNA and those by LVG (r = 0.61, r = 0.72 and r = 0.91, respectively; P < 0.01), and there was an excellent correlation between QGS and LVG (r = 0.73, r = 0.83 and r = 0.87, respectively; P < 0.01). The mean EDV by QGS (100 +/- 11.3 mL) was significantly lower than by FPRNA (132 +/- 16.8 mL) or LVG (130 +/- 8.1 mL), and the mean ESV by QGS (53.8 +/- 9.3 mL) was lower than by FPRNA (73.0 +/- 13.3 mL). Ejection fraction values were highest by LVG (57.1% +/- 3.2%), then QGS (51.8% +/- 3.0%) and FPRNA (48.9% +/- 2.4%).
Conclusion: QGS gave more reproducible results than FPRNA. LV volumes and LVEF calculated by QGS correlated well to those by LVG.
Similar articles
-
Assessment of left ventricular volume and ejection fraction: comparison of QGS and MBGS analyses of ECG-gated myocardial perfusion SPECT imaging.Nucl Med Commun. 2009 Apr;30(4):300-7. doi: 10.1097/MNM.0b013e3283294d19. Nucl Med Commun. 2009. PMID: 19357490
-
Gated myocardial perfusion SPECT: algorithm-specific influence of reorientation on calculation of left ventricular volumes and ejection fraction.J Nucl Med. 2008 Oct;49(10):1636-42. doi: 10.2967/jnumed.108.050484. Epub 2008 Sep 15. J Nucl Med. 2008. PMID: 18794266
-
Thallium-gated SPECT in patients with major myocardial infarction: effect of filtering and zooming in comparison with equilibrium radionuclide imaging and left ventriculography.J Nucl Med. 1999 Apr;40(4):513-21. J Nucl Med. 1999. PMID: 10210208
-
First-pass radionuclide angiocardiography with single-crystal gamma cameras.J Nucl Cardiol. 1997 Jan-Feb;4(1 Pt 1):61-73. doi: 10.1016/s1071-3581(97)90050-7. J Nucl Cardiol. 1997. PMID: 9138841 Review.
-
Technical introduction to nuclear imaging.Br Med Bull. 1989 Oct;45(4):838-47. doi: 10.1093/oxfordjournals.bmb.a072370. Br Med Bull. 1989. PMID: 2695215 Review.
Cited by
-
Gated SPECT in assessment of regional and global left ventricular function: major tool of modern nuclear imaging.J Nucl Cardiol. 2006 Mar-Apr;13(2):261-79. doi: 10.1007/BF02971251. J Nucl Cardiol. 2006. PMID: 16580963 Review. No abstract available.
-
Impact of photon energy recovery on the assessment of left ventricular volume using myocardial perfusion SPECT.J Nucl Cardiol. 2004 May-Jun;11(3):312-7. doi: 10.1016/j.nuclcard.2004.03.001. J Nucl Cardiol. 2004. PMID: 15173778 Clinical Trial.
-
Good correlation between gated single photon emission computed myocardial tomography and contrast ventriculography in the assessment of global and regional left ventricular function.Int J Card Imaging. 2000 Dec;16(6):447-53. doi: 10.1023/a:1010611412958. Int J Card Imaging. 2000. PMID: 11482710 Clinical Trial.
-
Assessment of left ventricular ejection fraction measured by quantitative gated SPECT: correlation with left ventriculography and first-pass radionuclide angiography.Int J Cardiovasc Imaging. 2006 Apr;22(2):223-30. doi: 10.1007/s10554-005-9014-2. Epub 2005 Oct 18. Int J Cardiovasc Imaging. 2006. PMID: 16231080
-
Comparison and co-relation of invasive and noninvasive methods of ejection fraction measurement.J Natl Med Assoc. 2007 Nov;99(11):1227-8, 1231-4. J Natl Med Assoc. 2007. PMID: 18020097 Free PMC article.