Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 1999 Oct 1;45(3):715-9.
doi: 10.1016/s0360-3016(99)00231-x.

External beam radiotherapy for painful osseous metastases: pooled data dose response analysis

Affiliations
Meta-Analysis

External beam radiotherapy for painful osseous metastases: pooled data dose response analysis

E Ben-Josef et al. Int J Radiat Oncol Biol Phys. .

Abstract

Purpose: Although the effectiveness of external beam irradiation in palliation of pain from osseous metastases is well established, the optimal fractionation schedule has not been determined. Clinical studies to date have failed to demonstrate an advantage for higher doses. To further address this issue, we conducted a pooled dose response analysis using data from published Phase III clinical trials.

Methods and materials: Complete response (CR) was used as an endpoint because it was felt to be least susceptible to inconsistencies in assessment.The biological effective dose (BED) was calculated for each schedule using the linear-quadratic model and an alpha/beta of 10. Using SAS version 6.12, the data were fitted using a weighted linear regression, a logistic model, and the spline technique. Finally, BED was categorized, and odds ratios for each level were calculated.

Results: CR was assessed early and late in 383 and 1,007 patients, respectively. Linear regression on the early-response data yielded a poor fit and a nonsignificant dose coefficient. With the late-response data, there was an excellent fit (R-square = 0.842) and a highly significant dose coefficient (p = 0.0002). Fitting early CR to a logistic model, we could not establish a significant dose response relationship. However, with the late-response data there was an excellent fit and the dose coefficient was significantly different from zero (0.017 +/- 0.00524; p = 0.0012). Application of the spline technique or removal of an outlier resulted in an improved fit (p = 0.048 and p = 0.0001, respectively). Using BED of < 14.4 Gy as a reference level, the odds ratios for late CR were 2.29-3.32 (BED of 19.5-51.4 Gy, respectively).

Conclusion: Our results demonstrate a clear dose-response for pain relief. Further testing of high intensity regiments is warranted.

PubMed Disclaimer

Publication types

LinkOut - more resources