Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Oct;76(10):692-9.

Rigid contact lens fitting relationships in keratoconus. Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group

Affiliations
  • PMID: 10524784

Rigid contact lens fitting relationships in keratoconus. Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group

T B Edrington et al. Optom Vis Sci. 1999 Oct.

Abstract

Purpose: Although the influence of flat-fitting contact lenses on corneal scarring in keratoconus is frequently debated, the current standard of care with regard to the apical fitting relationship in keratoconus remains undocumented.

Methods: Patients were examined at baseline in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study (N = 1209). Patients wearing a rigid contact lens in one or both eyes (N = 808) had their habitual rigid contact lenses analyzed, and the fluorescein patterns and base curves were compared to the first definite apical clearance lens (FDACL). The FDACL is the flattest lens in the CLEK Study trial lens set that exhibits an apical clearance fluorescein pattern. For patients wearing a rigid contact lens in both eyes, one eye was selected randomly for analysis.

Results: Twelve percent of the rigid contact lens-wearing eyes were wearing lenses fitted with apical clearance based upon the clinician's fluorescein pattern interpretation. The remainder (88%) was wearing lenses fitted with apical touch. For mild (steep keratometric reading <45 D) keratoconus corneas, the mean estimate of the base curve to cornea-fitting relationship was 1.18 D flat (SD +/- 1.84 D); moderate (steep keratometric reading: 45 to 52 D) corneas were fitted on average 2.38 D flat (SD +/- 2.56 D); and severe (steep keratometric reading > 52 D) corneas were fitted an average of 4.01 D flat (SD +/- 4.11 D).

Conclusions: Despite the potential risk for corneal scarring imposed by flat-fitting rigid contact lenses, most CLEK Study patients wear flat-fitting lenses. Overall, rigid lenses were fitted an average of 2.86 D (SD +/- 3.31 D) flatter than the FDACL.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources