Radiologic anatomy of ventricular assist devices
- PMID: 10524811
- DOI: 10.1097/00005382-199910000-00010
Radiologic anatomy of ventricular assist devices
Abstract
Ventricular assist devices (VAD) allow for long-term circulatory support of patients with end-stage heart failure. With the increasing duration of circulatory support, diagnostic imaging plays an important role in the management of patients on a VAD. The aim of our review was to analyze the radiologic features of different VADs. From 1987 to 1996, 319 patients (mean age 42 years, range 3 to 74 years) were treated with a VAD. A Berlin Heart VAD was implanted in 263 of the patients, the univentricular Baxtor Novacor was implanted in three patients, and the univentricular CI Heartmate was implanted in 19 patients. All patients were studied by serial chest radiographs. In addition, 70 patients underwent computed tomography (CT), and five patients underwent electron beam CT. The Berlin Heart VAD was used as a biventricular support system in 218 patients. In all cases, the position of the wire-directed cannulae was identified on the chest radiographs, while the exact position of the cannula tip could be visualized by CT only. The plastic cannulae of both the Novacor and the Heartmate were not discernible on radiographs, but required CT for evaluation. Computed tomography also resolved the metal components of the pumps. The titanium-made pump housing of the Heartmate caused beam-hardening artefacts that might conceal fluid accumulations in the pump pocket. Computed tomography is the standard of reference for examinations of cannula position, pump position, and pump components of ventricular assist devices.
Similar articles
-
Bridge to Transplantation With Long-Term Mechanical Assist Devices in Adults With Transposition of the Great Arteries.Artif Organs. 2019 Jan;43(1):90-96. doi: 10.1111/aor.13347. Epub 2018 Oct 28. Artif Organs. 2019. PMID: 30129258
-
Experience with over 1000 implanted ventricular assist devices.J Card Surg. 2008 May-Jun;23(3):185-94. doi: 10.1111/j.1540-8191.2008.00606.x. J Card Surg. 2008. PMID: 18435629
-
Ventricular assist device support in children and adolescents with heart failure: the Children's Medical Center of Dallas experience.Artif Organs. 2012 Jul;36(7):635-9. doi: 10.1111/j.1525-1594.2012.01443.x. Epub 2012 Apr 12. Artif Organs. 2012. PMID: 22497304
-
State of the art: implantable ventricular assist devices.Curr Opin Organ Transplant. 2009 Oct;14(5):554-9. doi: 10.1097/MOT.0b013e3283303750. Curr Opin Organ Transplant. 2009. PMID: 19667990 Review.
-
Building a bridge to save a failing ventricle: radiologic evaluation of short- and long-term cardiac assist devices.Radiographics. 2015 Mar-Apr;35(2):327-56. doi: 10.1148/rg.352140149. Radiographics. 2015. PMID: 25763721 Review.
Cited by
-
Imaging of mechanical cardiac assist devices.J Clin Imaging Sci. 2011;1:21. doi: 10.4103/2156-7514.80373. Epub 2011 May 2. J Clin Imaging Sci. 2011. PMID: 21966618 Free PMC article.
-
Conventional radiography and computed tomography of cardiac assist devices.Eur Radiol. 2009 Sep;19(9):2097-106. doi: 10.1007/s00330-009-1406-6. Epub 2009 May 1. Eur Radiol. 2009. PMID: 19408002 Clinical Trial.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical