Ozonation of blood during extracorporeal circulation. I. Rationale, methodology and preliminary studies
- PMID: 10532435
Ozonation of blood during extracorporeal circulation. I. Rationale, methodology and preliminary studies
Abstract
We investigated whether exposure of blood ex-vivo to oxygen-ozone (O2-O3) through a gas exchanger is feasible and practical. We first evaluated the classical dialysis-type technique but we soon realized that semipermeable membranes are unsuitable because they are hydrophilic and vulnerable to O3. We therefore adopted a system with hydrophobic O3-resistant hollow fibers enclosed in a polycarbonate housing with a membrane area of about 0.5 m2. First we tested the system with normal saline, determining the production of hydrogen peroxide (H2O2) at O3 concentrations from 5 to 40 microg/ml. We then evaluated critical parameters by circulating swine blood in vitro; this revealed that heparin is not an ideal anticoagulant for this system. Finally, we performed several experiments in sheep and defined optimal anticoagulant dose (sodium citrate, ACD), priming solution, volume of blood flow per min, volume and concentration of O2-O3 mixture flowing countercurrent with respect to blood and the time necessary for perfusion in vivo. The biochemical parameters showed that an O3 concentration as low as 10 microg/ml is effective; this means that gas exchange and O3 reactivity are rapid and capable of inducing biological effects. The sheep showed no adverse effects even after 50 min of extracorporeal circulation at higher O3 concentrations (20 to 40 microg/ml) but the exchanger became less effective (low pO2 values) due to progressive clogging with cells.
Similar articles
-
Ozonation of blood during extracorporeal circulation. II. Comparative analysis of several oxygenator-ozonators and selection of one type.Int J Artif Organs. 2001 Dec;24(12):890-7. Int J Artif Organs. 2001. PMID: 11831595
-
Oxygenation-ozonation of blood during extracorporeal circulation: in vitro efficiency of a new gas exchange device.Artif Organs. 2007 Sep;31(9):743-8. doi: 10.1111/j.1525-1594.2007.00448.x. Artif Organs. 2007. PMID: 17725702
-
Platelet function unaffected by ozonated autohaemotherapy in chronically haemodialysed patients.Blood Coagul Fibrinolysis. 2004 Oct;15(7):619-22. doi: 10.1097/00001721-200410000-00014. Blood Coagul Fibrinolysis. 2004. PMID: 15389131
-
Ozone therapy.Int J Artif Organs. 2004 Mar;27(3):168-75. doi: 10.1177/039139880402700303. Int J Artif Organs. 2004. PMID: 15112882 Review. No abstract available.
-
Ozone therapy in veterinary medicine: A review.Res Vet Sci. 2020 Jun;130:240-246. doi: 10.1016/j.rvsc.2020.03.026. Epub 2020 Mar 25. Res Vet Sci. 2020. PMID: 32234614 Review.
Cited by
-
Oxidative Stress and Neonatal Respiratory Extracorporeal Membrane Oxygenation.Front Physiol. 2018 Dec 4;9:1739. doi: 10.3389/fphys.2018.01739. eCollection 2018. Front Physiol. 2018. PMID: 30564143 Free PMC article. Review.
-
Homocysteine: Canary in the Coal Mine or Hidden Threat? A Biochemical Study on the Role of Plasma Thiols.FASEB J. 2025 Jul 15;39(13):e70772. doi: 10.1096/fj.202500677RR. FASEB J. 2025. PMID: 40577064 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical