Geometrically correct 3-D reconstruction of intravascular ultrasound images by fusion with biplane angiography--methods and validation
- PMID: 10534051
- DOI: 10.1109/42.796282
Geometrically correct 3-D reconstruction of intravascular ultrasound images by fusion with biplane angiography--methods and validation
Abstract
In the rapidly evolving field of intravascular ultrasound (IVUS), the assessment of vessel morphology still lacks a geometrically correct three-dimensional (3-D) reconstruction. The IVUS frames are usually stacked up to form a straight vessel, neglecting curvature and the axial twisting of the catheter during the pullback. Our method combines the information about vessel cross-sections obtained from IVUS with the information about the vessel geometry derived from biplane angiography. First, the catheter path is reconstructed from its biplane projections, resulting in a spatial model. The locations of the IVUS frames are determined and their orientations relative to each other are calculated using a discrete approximation of the Frenet-Serret formulas known from differential geometry. The absolute orientation of the frame set is established, utilizing the imaging catheter itself as an artificial landmark. The IVUS images are segmented, using our previously developed algorithm. The fusion approach has been extensively validated in computer simulations, phantoms, and cadaveric pig hearts.
Similar articles
-
Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound.Int J Card Imaging. 1997 Dec;13(6):451-62. doi: 10.1023/a:1005843222820. Int J Card Imaging. 1997. PMID: 9415847
-
A method for 3D reconstruction of coronary arteries using biplane angiography and intravascular ultrasound images.Comput Med Imaging Graph. 2005 Dec;29(8):597-606. doi: 10.1016/j.compmedimag.2005.07.001. Epub 2005 Nov 8. Comput Med Imaging Graph. 2005. PMID: 16278063
-
Fusion of angiography and intravascular ultrasound in vivo: establishing the absolute 3-D frame orientation.IEEE Trans Biomed Eng. 1999 Oct;46(10):1176-80. doi: 10.1109/10.790492. IEEE Trans Biomed Eng. 1999. PMID: 10513120
-
Three-dimensional reconstruction of coronary arteries with intravascular ultrasound.Herz. 1995 Aug;20(4):277-89. Herz. 1995. PMID: 7557831 Review.
-
Intravascular ultrasound in the coronary arteries.Semin Vasc Surg. 2006 Sep;19(3):132-8. doi: 10.1053/j.semvascsurg.2006.06.007. Semin Vasc Surg. 2006. PMID: 16996414 Review.
Cited by
-
Influence of material parameter variability on the predicted coronary artery biomechanical environment via uncertainty quantification.Biomech Model Mechanobiol. 2024 Jun;23(3):927-940. doi: 10.1007/s10237-023-01814-2. Epub 2024 Feb 15. Biomech Model Mechanobiol. 2024. PMID: 38361087 Free PMC article.
-
Three methods for accurate quantification of plaque volume in coronary arteries.Int J Cardiovasc Imaging. 2003 Aug;19(4):301-11. doi: 10.1023/a:1025470327543. Int J Cardiovasc Imaging. 2003. PMID: 14598898
-
IVUS-based FSI models for human coronary plaque progression study: components, correlation and predictive analysis.Ann Biomed Eng. 2015 Jan;43(1):107-21. doi: 10.1007/s10439-014-1118-1. Epub 2014 Sep 23. Ann Biomed Eng. 2015. PMID: 25245219 Free PMC article.
-
Validation of hemodynamic stress calculation in coronary computed tomography angiography versus intravascular ultrasound.Quant Imaging Med Surg. 2023 Apr 1;13(4):2339-2351. doi: 10.21037/qims-22-832. Epub 2023 Feb 9. Quant Imaging Med Surg. 2023. PMID: 37064396 Free PMC article.
-
Comparison of angiographic and IVUS derived coronary geometric reconstructions for evaluation of the association of hemodynamics with coronary artery disease progression.Int J Cardiovasc Imaging. 2016 Sep;32(9):1327-1336. doi: 10.1007/s10554-016-0918-9. Epub 2016 May 26. Int J Cardiovasc Imaging. 2016. PMID: 27229349
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical