Abstract
Objective: To evaluate the effect of verification bias on the accuracy of first-trimester nuchal translucency measurement for Down syndrome detection.
Methods: We used MEDLINE and EMBASE to identify all papers relating the results of nuchal translucency measurement to fetal karyotype. The detected studies were scored for verification bias. Fifteen studies without and ten with verification bias were included.
Results: Sensitivity and specificity were calculated for each study. For studies with verification bias, adjusted estimates of the sensitivity were calculated assuming a fetal loss rate for Down syndrome pregnancies of 48%. The sample size weighted sensitivity was 55% in studies without and 77% in those with verification bias, for specificities of 96% and 97%, respectively. After adjustment for verification bias, the sample size weighted sensitivity changed from 77% to 63%.
Conclusion: Studies with verification bias reported higher sensitivities, but also slightly higher specificities of nuchal translucency measurement than studies without verification bias. The difference in sensitivity is greater than could be explained by verification bias. We postulate that the experience of the sonographist might be an explanation for the differences.
Similar articles
-
Screening for Down syndrome using first-trimester ultrasound and second-trimester maternal serum markers in a low-risk population: a prospective longitudinal study.Ultrasound Obstet Gynecol. 2001 Jul;18(1):26-31. doi: 10.1046/j.1469-0705.2001.00457.x. Ultrasound Obstet Gynecol. 2001. PMID: 11489221
-
Screening for Down's syndrome by fetal nuchal translucency measurement in a general obstetric population.Ultrasound Obstet Gynecol. 1998 Sep;12(3):163-9. doi: 10.1046/j.1469-0705.1998.12030163.x. Ultrasound Obstet Gynecol. 1998. PMID: 9793187 Clinical Trial.
-
Screening for Down's syndrome by fetal nuchal translucency measurement in a high-risk population.Ultrasound Obstet Gynecol. 1998 Sep;12(3):156-62. doi: 10.1046/j.1469-0705.1998.12030156.x. Ultrasound Obstet Gynecol. 1998. PMID: 9793186 Clinical Trial.
-
[Down syndrome screening by ultrasound].Gynecol Obstet Fertil. 2005 Jul-Aug;33(7-8):526-32. doi: 10.1016/j.gyobfe.2005.05.021. Gynecol Obstet Fertil. 2005. PMID: 16005667 Review. French.
-
The use of nuchal translucency in contemporary obstetric practice.Clin Obstet Gynecol. 2008 Mar;51(1):37-47. doi: 10.1097/GRF.0b013e318160f2ea. Clin Obstet Gynecol. 2008. PMID: 18303498 Review.
Cited by
-
First and second trimester serum tests with and without first trimester ultrasound tests for Down's syndrome screening.Cochrane Database Syst Rev. 2017 Mar 15;3(3):CD012599. doi: 10.1002/14651858.CD012599. Cochrane Database Syst Rev. 2017. PMID: 28295159 Free PMC article.
-
Magnetic resonance imaging for diagnosing lumbar spinal pathology in adult patients with low back pain or sciatica: a diagnostic systematic review.Eur Spine J. 2012 Feb;21(2):220-7. doi: 10.1007/s00586-011-2019-8. Epub 2011 Sep 16. Eur Spine J. 2012. PMID: 21922287 Free PMC article.
-
Evidence of bias and variation in diagnostic accuracy studies.CMAJ. 2006 Feb 14;174(4):469-76. doi: 10.1503/cmaj.050090. CMAJ. 2006. PMID: 16477057 Free PMC article.
-
First trimester ultrasound tests alone or in combination with first trimester serum tests for Down's syndrome screening.Cochrane Database Syst Rev. 2017 Mar 15;3(3):CD012600. doi: 10.1002/14651858.CD012600. Cochrane Database Syst Rev. 2017. PMID: 28295158 Free PMC article.
-
Second trimester serum tests for Down's Syndrome screening.Cochrane Database Syst Rev. 2012 Jun 13;2012(6):CD009925. doi: 10.1002/14651858.CD009925. Cochrane Database Syst Rev. 2012. PMID: 22696388 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical