Limitations of characterization of hepatic hemangiomas using a sonographic contrast agent (Levovist) and power Doppler ultrasonography
- PMID: 10547105
- DOI: 10.7863/jum.1999.18.11.737
Limitations of characterization of hepatic hemangiomas using a sonographic contrast agent (Levovist) and power Doppler ultrasonography
Abstract
Power Doppler ultrasonography using a sonographic contrast agent (Levovist) was evaluated in 20 patients with hepatic hemangiomas with a 2-4 MHz convex transducer according to a standardized examination protocol (pulse repetition frequency, 1000 Hz; medium wall filter; power Doppler gain, 50 to 85%). Enhancement patterns were assessed and were compared with those on dynamic magnetic resonance imaging (n = 11) or computed tomography (n = 9). The most common enhancement pattern was dotlike or linear enhancement located predominantly at the periphery of the tumor (15 cases, 75%). Diffuse homogeneous enhancement was seen in one case (5%). No definite contrast enhancement was evident in four cases (20%). The enhanced area on ultrasonograms was smaller than that on dynamic MR images or CT scans in 18 cases (90%). A transient centripetal fill-in pattern was identified in six cases (30%). Persistent enhancement until 300 s was not seen in any case. Therefore, specific diagnosis of hemangioma with power Doppler ultrasonography and contrast agent may not be possible.
Similar articles
-
Hepatic hemangiomas: spectrum of US appearances on gray-scale, power Doppler, and contrast-enhanced US.Korean J Radiol. 2000 Oct-Dec;1(4):191-7. doi: 10.3348/kjr.2000.1.4.191. Korean J Radiol. 2000. PMID: 11752954 Free PMC article. Review.
-
Enhancement of hepatic hemangiomas with levovist on coded harmonic angiographic ultrasonography.J Ultrasound Med. 2002 Feb;21(2):141-8. doi: 10.7863/jum.2002.21.2.141. J Ultrasound Med. 2002. PMID: 11833870
-
[Characterization of focal liver lesions with contrast-enhanced low MI real time ultrasound and SonoVue].Rofo. 2003 Jun;175(6):835-43. doi: 10.1055/s-2003-39923. Rofo. 2003. PMID: 12811698 German.
-
Hemangiomas and focal nodular hyperplasia images in contrast-enhanced, wide-band phase-inversion harmonic power Doppler imaging.Med Sci Monit. 2004 Jun;10 Suppl 3:26-31. Med Sci Monit. 2004. PMID: 16538195
-
[Integrated diagnosis of liver angioma: comparison of Doppler color ultrasonography, computerized tomography, and magnetic resonance].Radiol Med. 1997 Jan-Feb;93(1-2):87-94. Radiol Med. 1997. PMID: 9380876 Review. Italian.
Cited by
-
Liver haemangiomas undetermined at grey-scale ultrasound: contrast-enhancement patterns with SonoVue and pulse-inversion US.Eur Radiol. 2005 Apr;15(4):685-93. doi: 10.1007/s00330-004-2569-9. Epub 2004 Dec 21. Eur Radiol. 2005. PMID: 15611873
-
Characterization of focal liver lesions with contrast-enhanced ultrasound.Eur Radiol. 2003 Nov;13 Suppl 3:N70-8. doi: 10.1007/s00330-003-0011-3. Eur Radiol. 2003. PMID: 15015885 Review. No abstract available.
-
Hepatic hemangiomas: spectrum of US appearances on gray-scale, power Doppler, and contrast-enhanced US.Korean J Radiol. 2000 Oct-Dec;1(4):191-7. doi: 10.3348/kjr.2000.1.4.191. Korean J Radiol. 2000. PMID: 11752954 Free PMC article. Review.
-
Focal hepatic lesions: evaluation with contrast-enhanced gray-scale harmonic US.Korean J Radiol. 2003 Apr-Jun;4(2):91-100. doi: 10.3348/kjr.2003.4.2.91. Korean J Radiol. 2003. PMID: 12845304 Free PMC article.
-
Assessment of hepatic VX2 tumors of rabbits with second harmonic imaging under high and low acoustic pressures.World J Gastroenterol. 2003 Aug;9(8):1679-82. doi: 10.3748/wjg.v9.i8.1679. World J Gastroenterol. 2003. PMID: 12918100 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical