Abstract
A fully digital radiography system requires high-fidelity electronic display devices that preserve diagnostic quality. Current cathode-ray tube monitors do not meet desired performance criteria for displaying radiographs and have excessive size, weight, and power consumption. Recent developments in flat-panel display technology (in particular active-matrix liquid crystal displays, field-emission displays, and organic light-emitting displays) suggest that high-fidelity, lightweight displays will be available in the near future. Large-size active-matrix liquid crystal display devices have been demonstrated. High brightness can be easily achieved with bright back illumination. Further developments in optical design for monochrome displays should provide high fidelity and improve the angular dependence of the emitted light. Field-emission display devices have attractive emission distribution and potential for low veiling glare. This technology needs to be extended to a large area, and problems with cathode aging and nonuniformity have to be contemplated. Organic light-emitting displays represent a simple and potentially inexpensive display technology with the ability to achieve high image quality. However, extensive research and development is required to achieve large-area manufacturing methods.
Similar articles
-
Angular dependence of the luminance and contrast in medical monochrome liquid crystal displays.Med Phys. 2003 Oct;30(10):2602-13. doi: 10.1118/1.1606449. Med Phys. 2003. PMID: 14596296
-
AAPM/RSNA tutorial on equipment selection: PACS equipment overview: display systems.Radiographics. 2004 May-Jun;24(3):879-89. doi: 10.1148/rg.243035133. Radiographics. 2004. PMID: 15143237 Review.
-
Variations in performance of LCDs are still evident after DICOM gray-scale standard display calibration.AJR Am J Roentgenol. 2010 Jul;195(1):181-7. doi: 10.2214/AJR.09.2851. AJR Am J Roentgenol. 2010. PMID: 20566814
-
[New computed radiography technologies in digital radiography].Radiologe. 2003 May;43(5):367-73. doi: 10.1007/s00117-003-0891-x. Radiologe. 2003. PMID: 12764585 German.
-
Principles of digital radiography with large-area, electronically readable detectors: a review of the basics.Radiology. 1999 Mar;210(3):595-9. doi: 10.1148/radiology.210.3.r99mr15595. Radiology. 1999. PMID: 10207454 Review. No abstract available.
Cited by
-
Perceived contrast on displays with different luminance ranges.Med Phys. 2022 Apr;49(4):2270-2278. doi: 10.1002/mp.15519. Epub 2022 Feb 15. Med Phys. 2022. PMID: 35119116 Free PMC article.
-
Influence of liquid crystal display monitors on observer performance for detection of diffuse pulmonary disease on chest radiographs.Radiat Med. 2007 Jun;25(5):211-7. doi: 10.1007/s11604-007-0126-6. Epub 2007 Jun 27. Radiat Med. 2007. PMID: 17581709
-
Performance of primary diagnostic monitors (PDMs) over time.J Appl Clin Med Phys. 2019 Dec;20(12):180-185. doi: 10.1002/acm2.12759. J Appl Clin Med Phys. 2019. PMID: 31833641 Free PMC article.
-
The influence of liquid crystal display (LCD) monitors on observer performance for the detection of nodular lesions on chest radiographs.Eur Radiol. 2006 Mar;16(3):726-32. doi: 10.1007/s00330-005-0030-3. Epub 2005 Nov 12. Eur Radiol. 2006. PMID: 16284772
-
Introduction to grayscale calibration and related aspects of medical imaging grade liquid crystal displays.J Digit Imaging. 2008 Jun;21(2):193-207. doi: 10.1007/s10278-007-9022-y. J Digit Imaging. 2008. PMID: 17333412 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources