Clinical Trial
. 1999 Aug;9(4):185-92.
doi: 10.1007/BF02330482.

Estimation of beat-to-beat changes in stroke volume from arterial pressure: a comparison of two pressure wave analysis techniques during head-up tilt testing in young, healthy men

Affiliations
Clinical Trial

Estimation of beat-to-beat changes in stroke volume from arterial pressure: a comparison of two pressure wave analysis techniques during head-up tilt testing in young, healthy men

W T Jellema et al. Clin Auton Res. 1999 Aug.

Abstract

Objective: The aim of this study was to compare beat-to-beat changes in stroke volume (SV) estimated by two different pressure wave analysis techniques during orthostatic stress testing: pulse contour analysis and Modelflow, i.e., simulation of a three-element model of aortic input impedance.

Methods: A reduction in SV was introduced in eight healthy young men (mean age, 25; range, 19-32 y) by a 30-minute head-up tilt maneuver. Intrabrachial and noninvasive finger pressure were monitored simultaneously. Beat-to-beat changes in SV were estimated from intrabrachial pressure by pulse contour analysis and Modelflow. In addition, the relative differences in Modelflow SV obtained from intrabrachial pressure and noninvasive finger pressure were assessed.

Results: Beat-to-beat changes in Modelflow SV from intrabrachial pressure were comparable with pulse contour measures. The relative difference between the two methods amounted to 0.1+/-1% (mean +/- SEM) and was not dependent on the duration of tilt. The difference between Modelflow applied to intrabrachial pressure and finger pressure amounted to -2.7+/-1.3% (p = 0.04). This difference was not dependent on the duration of tilt or level of arterial pressure.

Conclusions: Based on different mathematical models of the human arterial system, pulse contour and Modelflow compute similar changes in SV from intrabrachial pressure during orthostatic stress testing in young healthy men. The magnitude of the difference in SV derived from intrabrachial and finger pressure may vary among subjects; Modelflow SV from noninvasive finger pressure tracks fast and brisk changes in SV derived from intrabrachial pressure.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Acta Anaesthesiol Scand. 1995 Feb;39(2):245-51 - PubMed
    1. J Appl Physiol. 1970 Jul;29(1):133-7 - PubMed
    1. Circulation. 1996 Oct 15;94(8):1870-5 - PubMed
    1. Eur Heart J. 1993 Feb;14(2):160-7 - PubMed
    1. Eur Heart J. 1995 Nov;16(11):1641-54 - PubMed

Publication types

LinkOut - more resources