Biomechanical analysis of four supports for the subluxed hemiparetic shoulder
- PMID: 10575467
- DOI: 10.1177/000841749906600404
Biomechanical analysis of four supports for the subluxed hemiparetic shoulder
Abstract
External support systems, such as slings and lapboards, may reduce shoulder subluxation in individuals with hemiplegia. However there is controversy among occupational therapists concerning the most appropriate method to support the affected arm. The purpose of the present paper is to report the biomechanical analysis of four support systems; two shoulder support systems, a Bobath axillary roll, and a laptray. Two dimensional static biomechanical analyses determine the mechanical characteristics of each of these four support systems. The results of the analyses demonstrate the magnitude of the shoulder loading and the effectiveness of the various components of each of the systems. The effect of changing some of the characteristics of the slings is demonstrated. Slings with straps over the unaffected shoulder provide continuous support for the flaccid extremity. The Bobath axillary roll may introduce an unwanted lateral force. Lapboards must be maintained at an appropriate distance from the subluxed shoulder to be effective. This theoretical analysis of supports systems will provide therapists information to help them understand effective supports for subluxation.
Similar articles
-
Shoulder subluxation in hemiplegia: effects of three different supports.Arch Phys Med Rehabil. 1991 Jul;72(8):582-6. Arch Phys Med Rehabil. 1991. PMID: 2059138
-
Bobath axillary support for adults with hemiplegia. A biomechanical analysis.Phys Ther. 1988 Feb;68(2):228-32. doi: 10.1093/ptj/68.2.228. Phys Ther. 1988. PMID: 3340663
-
Shoulder supports revisited: a Canadian follow-up survey.Can J Occup Ther. 1999 Oct;66(4):161-8. doi: 10.1177/000841749906600403. Can J Occup Ther. 1999. PMID: 10575466
-
Glenohumeral subluxation in hemiplegia: An overview.J Rehabil Res Dev. 2005 Jul-Aug;42(4):557-68. doi: 10.1682/jrrd.2004.08.0112. J Rehabil Res Dev. 2005. PMID: 16320150 Review.
-
Therapeutic orthosis and electrical stimulation for upper extremity hemiplegia after stroke: a review of effectiveness based on evidence.Top Stroke Rehabil. 2004 Summer;11(3):9-15. doi: 10.1310/6Q5Q-69PU-NLQ9-AVMR. Top Stroke Rehabil. 2004. PMID: 15480949 Review.
Cited by
-
Supportive devices for preventing and treating subluxation of the shoulder after stroke.Cochrane Database Syst Rev. 2005 Jan 25;2005(1):CD003863. doi: 10.1002/14651858.CD003863.pub2. Cochrane Database Syst Rev. 2005. PMID: 15674917 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical