In vivo measurements of multi-component T2 relaxation behaviour in guinea pig brain
- PMID: 10576717
- DOI: 10.1016/s0730-725x(99)00064-8
In vivo measurements of multi-component T2 relaxation behaviour in guinea pig brain
Abstract
Multi-echo Carr-Purcell-Meiboom-Gill (CPMG) imaging sequences were implemented on 1.5 T and 4.0 T imaging systems to test their ability to measure in vivo multi-component T2 relaxation behavior in normal guinea pig brain. The known dependence of accurate T2 measurements on the signal-to-noise ratio (SNR) was explored in vivo by comparing T2 decay data obtained using three methods to increase SNR (improved RF coil design, signal averaging and increased magnetic field strength). Good agreement between T2 values of nickel-doped agarose phantoms was found between imaging and spectroscopic methods. T2 values were determined for gray matter (GM) and white matter (WM) locations from images of guinea pig brain in vivo. T2 measurements of GM were found to be monoexponential at both field strengths. The mean T2 times for GM were 71 ms at 1.5 T, and 53 ms at 4.0T. The highest average SNR was achieved using an improved RF coil at 4.0T. In this case, two peaks were extracted in WM, a "short" T2 peak at approximately 6 ms, and a "medium" T2 peak at approximately 48 ms. T2 values in GM and the major component of WM were significantly decreased at 4.0T compared to 1.5 T. The improved SNR attained with this optimized imaging protocol at 4.0T has allowed for the first time extraction of the myelin-sensitive T2 component of WM in animal brain in vivo.
Similar articles
-
Biexponential T2 relaxation time analysis of the brain: correlation with magnetization transfer ratio.Invest Radiol. 2002 Jul;37(7):363-7. doi: 10.1097/00004424-200207000-00001. Invest Radiol. 2002. PMID: 12068156
-
Magnetic field dependence of the distribution of NMR relaxation times in the living human brain.MAGMA. 2008 Mar;21(1-2):131-47. doi: 10.1007/s10334-008-0107-5. Epub 2008 Mar 13. MAGMA. 2008. PMID: 18338191
-
Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors: comparison of echo-planar, HASTE, and spin-echo sequences.Radiat Med. 2000 Jan-Feb;18(1):7-14. Radiat Med. 2000. PMID: 10852650
-
Quantitative T2 measurement of a single voxel with arbitrary shape using pinwheel excitation and CPMG acquisition.MAGMA. 2007 Dec;20(5-6):233-40. doi: 10.1007/s10334-007-0088-9. Epub 2007 Nov 13. MAGMA. 2007. PMID: 17999101 Free PMC article.
-
White and gray matter contrast enhancement in MR images of the mouse brain in vivo using IR UTE with a cryo-coil at 9.4 T.J Neurosci Methods. 2014 Jul 30;232:30-5. doi: 10.1016/j.jneumeth.2014.04.019. Epub 2014 May 5. J Neurosci Methods. 2014. PMID: 24809244
Cited by
-
Evaluation of white matter myelin water fraction in chronic stroke.Neuroimage Clin. 2013 Apr 21;2:569-80. doi: 10.1016/j.nicl.2013.04.006. eCollection 2013. Neuroimage Clin. 2013. PMID: 24179808 Free PMC article.
-
Myelin water and tensor-valued diffusion imaging: (How) are they related?Magn Reson Med. 2025 Nov;94(5):2038-2056. doi: 10.1002/mrm.30620. Epub 2025 Jul 1. Magn Reson Med. 2025. PMID: 40598716 Free PMC article.
-
Myelin water fraction decrease in individuals with chronic mild traumatic brain injury and persistent symptoms.Heliyon. 2021 Apr 6;7(4):e06709. doi: 10.1016/j.heliyon.2021.e06709. eCollection 2021 Apr. Heliyon. 2021. PMID: 33898831 Free PMC article.
-
Multi-components of T2 relaxation in ex vivo cartilage and tendon.J Magn Reson. 2009 Jun;198(2):188-96. doi: 10.1016/j.jmr.2009.02.005. Epub 2009 Feb 21. J Magn Reson. 2009. PMID: 19269868 Free PMC article.
-
Inter-Vendor Reproducibility of Myelin Water Imaging Using a 3D Gradient and Spin Echo Sequence.Front Neurosci. 2018 Nov 21;12:854. doi: 10.3389/fnins.2018.00854. eCollection 2018. Front Neurosci. 2018. PMID: 30519158 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical