Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 Nov;27(11):2337-45.
doi: 10.1097/00003246-199911000-00003.

Comparison of jugular venous oxygen saturation and brain tissue Po2 as monitors of cerebral ischemia after head injury

Affiliations
Comparative Study

Comparison of jugular venous oxygen saturation and brain tissue Po2 as monitors of cerebral ischemia after head injury

S P Gopinath et al. Crit Care Med. 1999 Nov.

Abstract

Objective: To compare the characteristics of jugular venous oxygen saturation (Sjvo2) and brain tissue Po2 (Pbto2) as monitors for cerebral ischemia after severe head injury. Sjvo2 has been useful as a monitor for cerebral ischemia, but it is limited by its inability to identify regional cerebral ischemia. Pbto2 may be superior to Sjvo2 for this purpose, because oxygenation in localized areas of the brain can be monitored.

Design: Sjvo2 and Pbto2 were successfully monitored in 58 patients with severe head injury. The changes in Sjvo2 and Pbto2 were compared during ischemic episodes.

Setting: Neurosurgical intensive care unit of a level I trauma center.

Measurements and main results: During the monitoring period, which averaged 90 hrs/patient, there were 54 episodes during which Sjvo2 decreased to <50% and/or Pbto2 decreased to <8 torr. Two of these episodes were caused by an infarction in the area of the Po2 probe, leaving 52 episodes of global hypoxia/ischemia that were identified by one of the two monitors. The sensitivities of the two monitors for detecting ischemia, using the thresholds of 50% and 8 torr for Sjvo2 and Pbto2, respectively, were similar. The Sjvo2 catheter detected 69.7% of the episodes and the Pbto2 catheter detected 63.5% of the episodes. In most of the remaining episodes, both probes reflected a decrease in oxygenation, but not to levels below the defined thresholds. The major differences in the two measures of oxygenation included the following: a) Sjvo2 more consistently reflected a reduction in oxygenation during hyperventilation; b) Pbto2 was affected more by changes in arterial Po2; and c) during severe global ischemia, Pbto2 decreased to 0 and remained at 0, whereas Sjvo2 initially decreased but then increased again as cerebral blood flow ceased, and the only blood in the jugular bulb was of extracerebral origin.

Conclusions: The two monitors provide complimentary information, and neither monitor alone identifies all episodes of ischemia. The best strategy for using these monitors is to take advantage of the unique features of each monitor. Sjvo2 should be used as a monitor of global oxygenation; but Pbto2 should be used as a monitor of local oxygenation, ideally with the catheter placed in an area of the brain that is vulnerable to ischemia but that may be salvageable with appropriate treatment.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources