Compliance of the respiratory system as a predictor for successful extubation in very-low-birth-weight infants recovering from respiratory distress syndrome
- PMID: 10582068
Compliance of the respiratory system as a predictor for successful extubation in very-low-birth-weight infants recovering from respiratory distress syndrome
Abstract
Objective: To develop additional criteria to predict for successful extubation of very-low-birth-weight infants recovering from respiratory distress syndrome.
Design: Prospective study.
Setting: Neonatal intensive care unit at a university teaching hospital.
Interventions: Infants ready for extubation according to clinical, ventilatory and blood gas criteria were studied. Before extubation, tidal volume (Vt), minute ventilation, respiratory rate/Vt and mean inspiratory flow were measured during two different ventilatory settings: (i) during intermittent mandatory ventilation (IMV); and (ii) while breathing spontaneously with endotracheal continuous positive airway pressure (CPAP). Tidal volume was obtained through electronically integrated flow measured by a hot-wire anemometer. Total respiratory compliance (Crs) was determined during IMV and was derived from the formula Vt/PIP-PEEP, where the difference between peak inspiratory pressure (PIP) and positive end-expiratory pressure (PEEP) represented the ventilator inflation pressure.
Measurements and main results: Each of 49 infants was studied once before extubation. 33 infants (67%) were successfully extubated and 16 (32.6%) required reintubation. Infants in the success and failure groups were matched for gestation, post-conceptional age, study weight and methylxanthine therapy at the time of study. Successful extubation was associated with a higher mean absolute Crs value (ml/cm H2O) specific Crs value (standardised for body length; ml/cm H2O/cm) compared with infants in whom extubation failed (0.67 v. 0.46; P = 0.01 and 0.018 v. 0.014; P = 0.03, respectively). Analysis of ROC curves detected thresholds for Crs (0.5 ml/cm H2O) and Vt (7 ml) for predicting successful extubation. An absolute Crs value 0.5 ml/cm H2O or more improved the likelihood of successful extubation when compared with clinical/ventilator and blood gas criteria. The likelihood of successful extubation was 81% if the Crs value was > or = 0.5 ml/cm H2O. A tidal volume of 7 ml or more was less sensitive in contributing to successful extubation (sensitivity 69%). The major causes for extubation failure included atelectasis (diffuse and/or localised) and the presence of a patent ductus arteriosus.
Conclusions: In addition to following very precise ventilatory criteria for extubation, we found that bedside measurement of total respiratory system compliance added to the likelihood of extubation success in infants recovering from respiratory distress syndrome. Prospective studies are needed to validate the findings of this study.
Similar articles
-
Predictors of successful extubation of preterm low-birth-weight infants with respiratory distress syndrome.Pediatr Crit Care Med. 2005 Jan;6(1):44-9. doi: 10.1097/01.PCC.0000149136.28598.14. Pediatr Crit Care Med. 2005. PMID: 15636658
-
Spontaneous minute ventilation is a predictor of extubation failure in extremely-low-birth-weight infants.J Matern Fetal Neonatal Med. 2004 Mar;15(3):147-54. doi: 10.1080/14767050410001668239. J Matern Fetal Neonatal Med. 2004. PMID: 15280139
-
Predictors of extubation success and failure in mechanically ventilated infants and children.Crit Care Med. 1996 Sep;24(9):1568-79. doi: 10.1097/00003246-199609000-00023. Crit Care Med. 1996. PMID: 8797633
-
Post-extubation prophylactic nasal continuous positive airway pressure in preterm infants: systematic review and meta-analysis.J Paediatr Child Health. 1999 Aug;35(4):367-71. J Paediatr Child Health. 1999. PMID: 10457294
-
Ventilator Liberation for High-Risk-for-Failure Patients: Improving Value of the Spontaneous Breathing Trial.Respir Care. 2015 Feb;60(2):290-6. doi: 10.4187/respcare.03111. Epub 2014 Oct 21. Respir Care. 2015. PMID: 25336534 Review.
Cited by
-
Predicting successful extubation of very low birthweight infants.Arch Dis Child Fetal Neonatal Ed. 2006 May;91(3):F180-3. doi: 10.1136/adc.2005.081083. Epub 2006 Jan 12. Arch Dis Child Fetal Neonatal Ed. 2006. PMID: 16410255 Free PMC article.
-
Prediction of Extubation readiness in extremely preterm infants by the automated analysis of cardiorespiratory behavior: study protocol.BMC Pediatr. 2017 Jul 17;17(1):167. doi: 10.1186/s12887-017-0911-z. BMC Pediatr. 2017. PMID: 28716018 Free PMC article.