Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 Dec 1;276(1):81-7.
doi: 10.1006/abio.1999.4336.

Simultaneous determination of alpha-fetoprotein and carcinoembryonic antigen in human serum by time-resolved fluoroimmunoassay

Affiliations
Comparative Study

Simultaneous determination of alpha-fetoprotein and carcinoembryonic antigen in human serum by time-resolved fluoroimmunoassay

K Matsumoto et al. Anal Biochem. .

Abstract

A novel simultaneous measurement method for alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) in human sera by time-resolved fluoroimmunoassay (TR-FIA) is described. The proposed approach combines the use of europium-labeled anti-AFP antibody for AFP TR-FIA and biotinylated anti-CEA antibody complexed to samarium-labeled streptavidin for CEA TR-FIA. A 96-well microtiter plate coated with a mixture of anti-AFP and anti-CEA monoclonal antibodies was used for the assay. After it was reacted with a solution containing AFP and CEA, a mixture of anti-AFP antibody labeled with BHHCT-Eu(3+) and biotinylated anti-CEA antibody was added. The AFP concentration was determined by measuring the solid-phase fluorescence of the europium-labeled anti-AFP antibody at 615 nm. Then a BHHCT-Sm(3+)-labeled streptavidin-bovine serum albumin conjugate (SA-BSA) was added to react with the biotinylated anti-CEA antibody. After the reaction, the unreacted SA-BSA was washed out, and a 0.1 M NaOH solution containing 1.0 x 10(-5) M TOPO and 0.05% SDS was added to dissociate the samarium-labeled SA-BSA in the immune complex on the surface of the well into the solution. The CEA concentration was determined by measuring the solution fluorescence of 643 nm from the samarium-labeled SA-BSA. The present method gives detection limits of 0.07 ng/ml for AFP and 0.3 ng/ml for CEA. The coefficient variations of the method are less than 7%, and the recoveries are in the range of 90-110% for serum samples. The AFP and CEA concentrations in 27 human serum samples were determined by the present method as well as by single assay for comparison. A good correlation was obtained with the correlation coefficients of 0.990 for AFP and 0.973 for CEA.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources