Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Nov 30;71(3-4):321-34.
doi: 10.1016/s0165-2427(99)00106-3.

The detection of CD2+, CD4+, CD8+, and WC1+ T lymphocytes, B cells and macrophages in fixed and paraffin embedded bovine tissue using a range of antigen recovery and signal amplification techniques

Affiliations

The detection of CD2+, CD4+, CD8+, and WC1+ T lymphocytes, B cells and macrophages in fixed and paraffin embedded bovine tissue using a range of antigen recovery and signal amplification techniques

M Gutierrez et al. Vet Immunol Immunopathol. .

Abstract

In order to develop procedures to label the main bovine leucocyte populations in paraffin embedded sections, the immunoreactivity of 25 monoclonal antibodies (mAbs) to different leucocyte antigens was assessed with formal dichromate (FD5) and 10% formalin fixation, a battery of antigen retrieval (AR) methods, and the biotin-tyramide amplification system. All the leucocyte populations investigated (CD2+, CD4+, CD8+, WC1+ T lymphocytes, B cells and macrophages) were strongly and specifically detectable under an appropriate combination of mAb, AR method and signal amplification system. CD4 and CD8 required the most stringent conditions and could only be demonstrated in FD5 fixed sections. For detection of CD2, WC1+ T lymphocytes, B cells and macrophages, all the mAbs produced immunoreactivity in FD5 or formalin fixed tissues. The need to check a range of different AR methods is stressed, as the method of choice varied for each individual mAb. The incorporation of the signal amplification system was necessary to observe a strong signal and the complete distribution of CD4, CD8 and B cells. Fixation by FD5 proved to be better than formalin for the preservation of surface antigens but it was inferior for the detection of markers which were found to show cytoplasmic immunoreactivity, such as the macrophage marker MAC387 or the B cell markers BAQ155 or IL-A59.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources