Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1999 Dec;116(6):635-41.
doi: 10.1016/s0889-5406(99)70198-8.

An in vitro evaluation of a metal reinforced orthodontic ceramic bracket

Affiliations
Comparative Study

An in vitro evaluation of a metal reinforced orthodontic ceramic bracket

K S Mundstock et al. Am J Orthod Dentofacial Orthop. 1999 Dec.

Abstract

The objectives of the present study were to measure and compare the bond strength and failure sites of a currently available ceramic bracket (Transcend 3M-Unitek) with the new metal reinforced ceramic bracket (Clarity 3M-Unitek) and to evaluate the amount of composite left on the tooth using the Adhesive Remnant Index in the teeth that were debonded with pliers recommended for this purpose. In addition, the presence or absence of enamel damage after debonding was also assessed. One hundred and twenty extracted premolar teeth were divided into 4 groups of 30 each. Two groups of 30 teeth had Transcend 6000 brackets bonded, and the other 2 groups had Clarity brackets bonded. Shear bond strength was carried out on 30 Transcend 6000 brackets and 30 Clarity brackets, whereas the other 2 groups of 30 teeth bonded with Transcend 6000 and Clarity brackets were debonded with debonding pliers recommended by the manufacturer of both ceramic brackets. The mean shear bond strength of the Clarity brackets was 13.27 MPa, whereas that of the Transcend 6000 was 21.19 MPa. Both brackets failed mostly at the bracket-adhesive interface (75%), indicating a possible reduction of the chances of enamel damage. Six of the premolars, bonded with Transcend 6000 brackets and debonded with the plier, showed an increase in the number or length of enamel cracks as evaluated by an optical microscope (Micro-Vu); one premolar, bonded with Clarity brackets and debonded with the pliers, showed an increased enamel crack length. Gross enamel damage, assessed by enamel dislodgment, was not evident in any specimen. Results of this study suggest that the new metal reinforced ceramic bracket (Clarity) may be recommended for clinical use because of its acceptable shear bond strength and possible reduced chances of enamel damage during bracket removal.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources