Hyperemic coronary flow after optimized intravascular ultrasound-guided balloon angioplasty and stent implantation
- PMID: 10588201
- DOI: 10.1016/s0735-1097(99)00450-7
Hyperemic coronary flow after optimized intravascular ultrasound-guided balloon angioplasty and stent implantation
Abstract
Objectives: This study evaluated the acute physiological gain of adjunctive intravascular ultrasound (IVUS) guided balloon angioplasty and stent implantation.
Background: Recent studies indicate safe coronary luminal enlargement and "stent-like" long-term outcomes using upsized balloons guided by IVUS.
Methods: After angiographically guided balloon angioplasty in 20 patients with 1-vessel disease and normal left ventricular function, IVUS was performed to determine the size of the adjunctive balloon using the mean of the maximal luminal diameter and the maximal diameter of the external elastic membrane measured in the adjacent proximal and distal reference segments. Serial adenosine-induced hyperemic blood flow velocity measurements were performed using a 0.014" Doppler guide wire to determine the physiological lumen obstruction after standard balloon angioplasty, followed by IVUS-guided balloon angioplasty and stent implantation.
Results: Upsized balloon angioplasty (increase balloon size: 0.98 +/- 0.26 mm; balloon:artery ratio 1.35 +/- 0.21) resulted in an additional increase of arterial dimensions: minimal lumen diameter (MLD) 2.18 +/- 0.38 mm to 2.73 +/- 0.51 mm; percent diameter stenosis (%DS) 34 +/- 13% to 19 +/- 22%; IVUS assessed minimal lumen area (MLA) 7.53 +/- 1.55 mm2 to 10.24 +/- 2.22 mm2 (all p < 0.0001). Major dissections (> or = type C) did not occur. Hyperemic blood flow velocity increased from 49.8 +/- 20.1 cm/s to 59.1 +/- 22.9 cm/s (p < 0.05) after IVUS-guided balloon angioplasty. Adjunctive stent implantation resulted in a further increase of MLD to 3.84 +/- 0.51 mm, %DS to -9 +/- 21% and MLA to 13.39 +/- 1.80 mm2 (all p < 0.0001), while hyperemic blood flow velocity remained unchanged (61.2 +/- 24.7 cm/s, p = 0.7).
Conclusions: Upsized IVUS-guided balloon angioplasty increases arterial coronary dimensions and the distal hyperemic blood flow velocity. Adjunctive stent implantation does not yield a further gain in the hyperemic blood flow velocity, indicating the absence of a functional residual lumen obstruction after IVUS-guided balloon angioplasty. This may explain a similar clinical outcome reported after those coronary interventions.
Comment in
-
Optimal balloon angioplasty versus elective stent implantation.J Am Coll Cardiol. 1999 Dec;34(7):1907-9. doi: 10.1016/s0735-1097(99)00458-1. J Am Coll Cardiol. 1999. PMID: 10588202 Review. No abstract available.
Similar articles
-
Role of coronary artery lumen enlargement in improving coronary blood flow after balloon angioplasty and stenting: a combined intravascular ultrasound Doppler flow and imaging study.J Am Coll Cardiol. 1997 Jun;29(7):1520-7. doi: 10.1016/s0735-1097(97)00082-x. J Am Coll Cardiol. 1997. PMID: 9180114
-
[Normalization of myocardial perfusion reserve after coronary stent implantation in comparison with balloon angioplasty alone].Z Kardiol. 1996 Apr;85(4):260-72. Z Kardiol. 1996. PMID: 8693769 German.
-
Standardized angiographically guided over-dilatation of stents using high pressure technique optimize results without increasing risks.J Invasive Cardiol. 2002 May;14(5):221-6. J Invasive Cardiol. 2002. PMID: 11983940 Clinical Trial.
-
Intravascular ultrasonography in the evaluation of results of coronary angioplasty and stenting.Curr Opin Cardiol. 1999 Nov;14(6):471-9. doi: 10.1097/00001573-199911000-00004. Curr Opin Cardiol. 1999. PMID: 10579062 Review.
-
[New methods of coronary imaging II. Intracoronary ultrasonography in clinical practice].Ital Heart J Suppl. 2001 Jun;2(6):579-92. Ital Heart J Suppl. 2001. PMID: 11460831 Review. Italian.
Cited by
-
Transthoracic Doppler echocardiography - noninvasive diagnostic window for coronary flow reserve assessment.Cardiovasc Ultrasound. 2003 Apr 11;1:4. doi: 10.1186/1476-7120-1-4. Cardiovasc Ultrasound. 2003. PMID: 12740038 Free PMC article. Review.
-
Progression of detail.J Nucl Cardiol. 2000 Mar;7(2):177-9. doi: 10.1016/S1071-3581(00)90041-2. J Nucl Cardiol. 2000. PMID: 27517559 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources