Comparison of three commercial assays for the quantification of HIV-1 RNA in plasma from individuals infected with different HIV-1 subtypes
- PMID: 10588451
- DOI: 10.1016/s1386-6532(99)00053-0
Comparison of three commercial assays for the quantification of HIV-1 RNA in plasma from individuals infected with different HIV-1 subtypes
Abstract
Background: Commercial human immunodeficiency virus 1 (HIV-1) ribonucleic acid (RNA) quantification assays vary in their ability to quantify different subtypes of HIV-1, a problem in regions where multipte HIV-1 subtypes may be circulating.
Objectives: To assess commercial HIV-1 RNA quantification assays on two plasma panels. Panel 1 consisted of HIV-1 seronegative plasma 'spiked' with a known amount of cultured virus of different subtypes, and Panel 2 comprised plasma collected from individuals infected with different HIV-1 subtypes.
Study design: The comparison involved the Amplicor HIV-1 reverse transcriptase-polymerase chain reaction (RT-PCR), Quantiplex branched DNA, and NucliSens HIV-1 QT assays. Panel 1 consisted of 11 plasma 'spiked' with cultured viruses of HIV-1 subtypes A-F, and Panel 2 included 33 plasma samples from 16 patients infected with subtypes A, B, C, E and G.
Results: In Panel 1, the Quantiplex branched deoxyribonucleic acid (bDNA) assay quantified subtypes A-F efficiently, comparable to published results from two other laboratories. The Amplicor RT-PCR assay quantified subtypes B, C, and D but was relatively less efficient with subtypes E, F, and did not or poorly quantified subtype A. Testing of Panel 2 showed some inter-assay differences. In contrast to Panel 1, the Amplicor RT-PCR assay performed variably with subtype A when compared with the Quantiplex bDNA and NucliSens QT assays, and higher viral load levels were generated with subtype E using the Amplicor RT-PCR assay. Subtypes B and C showed some inter-patient differences but the Quantiplex bDNA generally gave a lower quantification than the Amplicor RT-PCR and NucliSens QT assays.
Conclusions: These studies confirm that commercial HIV-1 load assays vary in their ability to quantify different HIV-1 subtypes. This may be more apparent with individual patient samples than with 'spiked' panels. This variability emphasizes that it is preferable for patient samples to be tested with the same assay, and care should be taken where infection with unusual subtypes is suspected.
Similar articles
-
Multicenter comparison of Roche COBAS AMPLICOR MONITOR version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma.J Clin Microbiol. 2000 Nov;38(11):4034-41. doi: 10.1128/JCM.38.11.4034-4041.2000. J Clin Microbiol. 2000. PMID: 11060065 Free PMC article.
-
Quantitative and cost comparison of ultrasensitive human immunodeficiency virus type 1 RNA viral load assays: Bayer bDNA quantiplex versions 3.0 and 2.0 and Roche PCR Amplicor monitor version 1.5.J Clin Microbiol. 2000 Mar;38(3):1113-20. doi: 10.1128/JCM.38.3.1113-1120.2000. J Clin Microbiol. 2000. PMID: 10699005 Free PMC article.
-
Comparison of three different commercial methods for measuring plasma viraemia in patients infected with non-B HIV-1 subtypes.Eur J Clin Microbiol Infect Dis. 1999 Apr;18(4):256-9. doi: 10.1007/s100960050273. Eur J Clin Microbiol Infect Dis. 1999. PMID: 10385013
-
Molecular-based methods for quantifying HIV viral load.AIDS Patient Care STDS. 2004 Feb;18(2):75-9. doi: 10.1089/108729104322802506. AIDS Patient Care STDS. 2004. PMID: 15006182 Review.
-
The significance of HIV viral load assay precision: a review of the package insert specifications of two commercial kits.J Int Assoc Physicians AIDS Care (Chic). 2002 Oct-Dec;1(4):134-40. doi: 10.1177/154510970200100405. J Int Assoc Physicians AIDS Care (Chic). 2002. PMID: 12942672 Review.
Cited by
-
Evidence that low-level viremias during effective highly active antiretroviral therapy result from two processes: expression of archival virus and replication of virus.J Virol. 2005 Aug;79(15):9625-34. doi: 10.1128/JVI.79.15.9625-9634.2005. J Virol. 2005. PMID: 16014925 Free PMC article.
-
Comparison of Roche MONITOR and Organon Teknika NucliSens assays to quantify human immunodeficiency virus type 1 RNA in cerebrospinal fluid.J Clin Microbiol. 2001 Apr;39(4):1612-4. doi: 10.1128/JCM.39.4.1612-1614.2001. J Clin Microbiol. 2001. PMID: 11283098 Free PMC article.
-
Segregation of human immunodeficiency virus type 1 subtypes by risk factor in Australia.J Clin Microbiol. 2003 Oct;41(10):4600-4. doi: 10.1128/JCM.41.10.4600-4604.2003. J Clin Microbiol. 2003. PMID: 14532189 Free PMC article.
-
Multicenter evaluation of the performance characteristics of the NucliSens HIV-1 QT assay used for quantitation of human immunodeficiency virus type 1 RNA.J Clin Microbiol. 2003 Jan;41(1):164-73. doi: 10.1128/JCM.41.1.164-173.2003. J Clin Microbiol. 2003. PMID: 12517843 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical