Evaluation of platelet function with the PFA-100 system in patients with congenital defects of platelet secretion
- PMID: 10588464
- DOI: 10.1016/s0049-3848(99)00102-4
Evaluation of platelet function with the PFA-100 system in patients with congenital defects of platelet secretion
Abstract
The template bleeding time is still the screening test for defects of platelet function, although it is an invasive and poorly reproducible technique. The PFA-100 measures platelet function at high shear. Whole blood is aspirated through a capillary to an aperture of a membrane coated with platelet agonists. The system measures the time required to obtain occlusion of the aperture by a platelet plug (closure time). We measured the closure times in the PFA-100 system and the bleeding time in seven patients with delta-storage pool deficiency, 10 patients with "primary secretion defect" (not due to abnormalities of platelet granules or the arachidonate pathway), and 40 controls. Measurements were repeated I and 4 hours after intravenous infusion of desmopressin in six delta-storage pool deficiency and eight primary secretion defect patients. Baseline bleeding time and closure times with the collagen/epinephrine cartridge were longer in delta-storage pool deficiency and primary secretion defect patients than in controls. In contrast, closure times with the collagen/adenosine diphosphate cartridge were normal in both delta-storage pool deficiency and primary secretion defect patients. Treatment with desmopressin increased the plasma von Willebrand Factor levels, shortened the prolonged bleeding time, shortened the closure times with the collagen/adenosine diphosphate cartridge, and normalized the closure times with the collagen/ epinephrine cartridge. Therefore, the PFA-100 test may be a less invasive alternative to the bleeding time in the diagnosis and therapeutic monitoring of patients with platelet secretion defects. The collagen/epinephrine cartridge is more sensitive than the collagen/adenosine diphosphate cartridge to defects of platelet secretion.
Similar articles
-
Usefulness of the INNOVANCE PFA P2Y test cartridge for the detection of patients with congenital defects of the platelet P2Y₁₂ receptor for adenosine diphosphate.Thromb Res. 2014 Feb;133(2):254-6. doi: 10.1016/j.thromres.2013.11.022. Epub 2013 Dec 1. Thromb Res. 2014. PMID: 24331208
-
Platelet aggregation at high shear is impaired in patients with congenital defects of platelet secretion and is corrected by DDAVP: correlation with the bleeding time.J Lab Clin Med. 1995 Apr;125(4):540-7. J Lab Clin Med. 1995. PMID: 7706911
-
Evaluation of a Platelet Function Analyser (PFA-100) in patients with a bleeding tendency.Swiss Med Wkly. 2002 Aug 10;132(31-32):443-8. doi: 10.4414/smw.2002.10039. Swiss Med Wkly. 2002. PMID: 12457302 Clinical Trial.
-
External quality assessment/proficiency testing and internal quality control for the PFA-100 and PFA-200: an update.Semin Thromb Hemost. 2014 Mar;40(2):239-53. doi: 10.1055/s-0034-1365844. Epub 2014 Feb 4. Semin Thromb Hemost. 2014. PMID: 24497116 Review.
-
Towards 50 years of platelet function analyser (PFA) testing.Clin Chem Lab Med. 2022 Jul 21;61(5):851-860. doi: 10.1515/cclm-2022-0666. Print 2023 Apr 25. Clin Chem Lab Med. 2022. PMID: 35859143 Review.
Cited by
-
Multiparameter platelet function analysis of bleeding patients with a prolonged platelet function analyser closure time.Br J Haematol. 2022 Mar;196(6):1388-1400. doi: 10.1111/bjh.18003. Epub 2022 Jan 10. Br J Haematol. 2022. PMID: 35001370 Free PMC article.
-
[Significance of platelet function tests].Internist (Berl). 2010 Sep;51(9):1095-6, 1098-100, 1102-8. doi: 10.1007/s00108-009-2569-6. Internist (Berl). 2010. PMID: 20700570 Review. German.
-
A Review of Desmopressin Use in Bleeding Disorders: An Unsung Hero?Biomolecules. 2025 Jul 5;15(7):967. doi: 10.3390/biom15070967. Biomolecules. 2025. PMID: 40723839 Free PMC article. Review.
-
Von Willebrand disease: an overview.Indian J Pharm Sci. 2011 Jan;73(1):7-16. doi: 10.4103/0250-474X.89751. Indian J Pharm Sci. 2011. PMID: 22131616 Free PMC article.
-
Utility of the Platelet Function Analyzer in Patients with Suspected Platelet Function Disorders: Diagnostic Accuracy Study.TH Open. 2020 Dec 22;4(4):e427-e436. doi: 10.1055/s-0040-1721502. eCollection 2020 Oct. TH Open. 2020. PMID: 33376942 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical