Effects of crystalloid and colloid preload on blood volume in the parturient undergoing spinal anesthesia for elective Cesarean section
- PMID: 10598596
- DOI: 10.1097/00000542-199912000-00006
Effects of crystalloid and colloid preload on blood volume in the parturient undergoing spinal anesthesia for elective Cesarean section
Abstract
Background: The role of crystalloid preloading to prevent hypotension associated with spinal anesthesia in parturients during cesarean section has been challenged. Direct measurement of blood volume should provide insight regarding the volume-expanding effects. The aim of the current study was to clarify the effects of volume preload with either crystalloid or colloid solution on the changes in blood volume of parturients undergoing spinal anesthesia for cesarean section.
Methods: Thirty-six healthy parturients scheduled for elective cesarean section during spinal anesthesia were allocated randomly to one of three groups receiving 1.5 l lactated Ringer's solution (LR; n = 12), 0.5 l hydroxyethylstarch solution, 6% (0.5 l HES; n = 12), and 1.0 l hydroxyethylstarch solution, 6% (1.0 l HES; n = 12), respectively. Blood volume and cardiac output were measured before and after volume preloading with indocyanine green (ICG), and the indocyanine green blood concentrations were monitored by noninvasive pulse spectrophotometry.
Results: After volume preload, the blood volume significantly increased in all three groups (P < 0.01). The volume of infused solution remaining in the vascular space in the LR, 0.5-l HES, and 1.0-l HES groups were 0.43+/-0.20 l, 0.54+/-0.14 l, and 1.03+/-0.21 l, respectively, corresponding to 28% of lactated Ringer's solution and 100% of hydroxyethylstarch solution infused. Significant increases in cardiac output were observed in the 0.5-l and 1.0-l HES groups (P < 0.01). A significant correlation between the percentage increase in blood volume and that of cardiac output was observed by volume preloading (r2 = 0.838; P < 0.001). The incidence of hypotension was 75% for the LR group, 58% for the 0.5-l HES group, and 17% for the 1.0-l HES group, respectively.
Conclusions: The incidence of hypotension developed in the 1.0-l HES group was significantly lower than that in the LR and 0.5-l HES groups, showing that greater volume expansion results in less hypotension. This result indicates that the augmentation of blood volume with preloading, regardless of the fluid used, must be large enough to result in a significant increase in cardiac output for effective prevention of hypotension.
Comment in
-
Spinal hypotension associated with Cesarean section: will preload ever work?Anesthesiology. 1999 Dec;91(6):1565-7. doi: 10.1097/00000542-199912000-00004. Anesthesiology. 1999. PMID: 10598594 No abstract available.
-
Which parameter measures the effectiveness of volume preload in pregnant patients?Anesthesiology. 2000 Nov;93(5):1364-5. doi: 10.1097/00000542-200011000-00041. Anesthesiology. 2000. PMID: 11046234 No abstract available.
Similar articles
-
The effects of crystalloid and colloid preload on cardiac output in the parturient undergoing planned cesarean delivery under spinal anesthesia: a randomized trial.Anesth Analg. 2009 Dec;109(6):1916-21. doi: 10.1213/ANE.0b013e3181bbfdf6. Anesth Analg. 2009. PMID: 19923521 Clinical Trial.
-
[Comparison of the effects of colloid and crystalloid solution for volume preloading on maternal hemodynamics and neonatal outcome in spinal anesthesia for cesarean section].Masui. 2004 Sep;53(9):1019-24. Masui. 2004. PMID: 15500103 Clinical Trial. Japanese.
-
Maternal cardiac output changes after crystalloid or colloid coload following spinal anesthesia for elective cesarean delivery: a randomized controlled trial.Anesth Analg. 2011 Oct;113(4):803-10. doi: 10.1213/ANE.0b013e31822c0f08. Epub 2011 Sep 2. Anesth Analg. 2011. PMID: 21890886 Clinical Trial.
-
Colloids versus crystalloids in the prevention of hypotension induced by spinal anesthesia in elective cesarean section. A systematic review and meta-analysis.Minerva Anestesiol. 2015 Sep;81(9):1019-30. Epub 2014 Dec 11. Minerva Anestesiol. 2015. PMID: 25501602
-
Cesarean delivery fluid management.Curr Opin Anaesthesiol. 2012 Jun;25(3):286-91. doi: 10.1097/ACO.0b013e3283530dab. Curr Opin Anaesthesiol. 2012. PMID: 22459983 Review.
Cited by
-
Effects of rapid fluid infusion on hemoglobin concentration: a systematic review and meta-analysis.Crit Care. 2022 Oct 23;26(1):324. doi: 10.1186/s13054-022-04191-x. Crit Care. 2022. PMID: 36274172 Free PMC article.
-
Complexity of blood volume control system and its implications in perioperative fluid management.J Anesth. 2009;23(4):534-42. doi: 10.1007/s00540-009-0797-5. Epub 2009 Nov 18. J Anesth. 2009. PMID: 19921364 Review.
-
Determination of the standard value of circulating blood volume during anesthesia using pulse dye-densitometry: a multicenter study in Japan.J Anesth. 2005;19(3):193-8. doi: 10.1007/s00540-005-0320-6. J Anesth. 2005. PMID: 16032445
-
Crystalloid coloading vs. colloid coloading in elective Caesarean section: postspinal hypotension and vasopressor consumption, a prospective, observational clinical trial.J Anesth. 2019 Feb;33(1):40-49. doi: 10.1007/s00540-018-2581-x. Epub 2018 Dec 6. J Anesth. 2019. PMID: 30523408
-
Comparison Between the Effects of Ringer`s Lactate and Hydroxyethyl Starch on Hemodynamic Parameters After Spinal Anesthesia: A Randomized Clinical Trial.Anesth Pain Med. 2013 Winter;2(3):127-33. doi: 10.5812/aapm.7850. Epub 2013 Jan 1. Anesth Pain Med. 2013. PMID: 24244923 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical