Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1999 Dec 21;201(4):219-29.
doi: 10.1006/jtbi.1999.1024.

Timing accuracy in human throwing

Affiliations

Timing accuracy in human throwing

A G Chowdhary et al. J Theor Biol. .

Abstract

This study examines the precision required in the timing of muscle activations and projectile release to hit a target of 20 cm in diameter oriented horizontally either 6 or 8 m away. Over-arm throws, constrained to the sagittal plane, were simulated using a muscle-actuated, two-segment model representing the forearm and hand plus projectile. The parameters defining the modeled muscles and the anthropometry were specific to two male subjects. An objective function specified that throws must be both fast and accurate. Once an optimal solution had been found, the sensitivity of these timings was investigated. The times of activation or release were changed and the simulation model re-run with the new timings, and it was determined whether the projectile would still have struck the target. For one set of simulations, to hit the target at 8 m, the optimal throw was achieved with a time delay between the onset of wrist activation and elbow extensor activation [Proximal-distal (PD) delay] of 49 ms and a release time of 83.4 ms. At this optimal point in the solution space, the launch window was 1.2 ms (assuming the original PD delay). The launch window was the time available within which the projectile must be released and still strike the target. The window during which the wrist flexors could be activated was 10. 41 ms (assuming the projectile was released at the pre-planned optimal time). The control scheme which required the least timing precision had a PD delay of 56 ms and a release time of 89.4 ms. Errors in timing could occur in activation and release simultaneously under this scheme, the timing windows were 4 ms in PD delay and 2.4 ms in release. Similar results were found for a second set of simulations. These simulations revealed the precise timings required in muscle activations and release required for fast accurate throws.

PubMed Disclaimer

LinkOut - more resources