Ceramic bearing surfaces
- PMID: 10611863
- DOI: 10.1097/00003086-199912000-00009
Ceramic bearing surfaces
Abstract
Despite more than 25 years of clinical experience with ceramic materials as bearing surfaces, their role in modern joint replacement surgery remains to be clearly defined. The two primary materials are alumina and zirconia. The application of these materials is primarily as a femoral head bearing surface against polyethylene, but alumina also is used as a femoral head and an acetabulum to provide a polyethylene-free bearing surface. Important issues that must be clarified for these materials to gain wide acceptance are the material properties, wear rates against polyethylene and alumina, the biologic response to ceramic wear debris, and cost in relation to indications. The bulk materials are biocompatible, hard, wettable, high-strength, and can yield good surface finishes. Linear polyethylene wear against alumina heads is reported to be as much as a factor of 5 to 10 lower than metal versus polyethylene. Thus, the ceramic femoral head may be a good choice for the younger patient in whom it seems necessary to use a larger head for stability reasons with a polyethylene cup. Ceramic-on-ceramic wear rates are in the range of 0.003 mm/year, a factor of 10 less than the lowest polyethylene wear rates. These costly materials are limited in head and neck sizes because of statistical variation in strength that can lead to fracture. Occasional reports of high alumina-on-alumina wear have appeared. Many of the problems of the past have been design, manufacture, or application related, and have been improved or eliminated. Proper clinical technique in the use of ceramic femoral heads is crucial to prevent fracture. The materials hold high promise and should continue to be used so that additional experience can help define the clinical indications for components made of these materials.
Similar articles
-
Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.Clin Orthop Relat Res. 2015 Dec;473(12):3836-45. doi: 10.1007/s11999-015-4503-7. Clin Orthop Relat Res. 2015. PMID: 26290343 Free PMC article. Clinical Trial.
-
Alumina Delta-on-Highly Crosslinked-Remelted Polyethylene Bearing in Cementless Total Hip Arthroplasty in Patients Younger than 50 Years.J Arthroplasty. 2016 Dec;31(12):2800-2804. doi: 10.1016/j.arth.2016.05.020. Epub 2016 May 18. J Arthroplasty. 2016. PMID: 27378639
-
Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.Clin Orthop Relat Res. 2015 Dec;473(12):3829-35. doi: 10.1007/s11999-015-4422-7. Clin Orthop Relat Res. 2015. PMID: 26122983 Free PMC article.
-
The case for ceramic-on-polyethylene as the preferred bearing for a young adult hip replacement.Hip Int. 2014 Sep-Oct;24(5):421-7. doi: 10.5301/hipint.5000138. Epub 2014 Apr 17. Hip Int. 2014. PMID: 24817396 Review.
-
Alternative materials to improve total hip replacement tribology.Acta Orthop Scand. 2003 Aug;74(4):380-8. doi: 10.1080/00016470310017668. Acta Orthop Scand. 2003. PMID: 14521286 Review.
Cited by
-
Adverse Reaction to Zirconia in a Modern Total Hip Arthroplasty with Ceramic Head.Arthroplast Today. 2020 Jun 19;6(3):612-616.e1. doi: 10.1016/j.artd.2020.03.009. eCollection 2020 Sep. Arthroplast Today. 2020. PMID: 32995410 Free PMC article.
-
Suboptimal Component Position Leading to Severe Wear of an Alumina-Alumina Total Hip Coupling: Biomechanical Analysis and Documentation of Limited Tissue Response.HSS J. 2015 Jul;11(2):166-71. doi: 10.1007/s11420-015-9443-y. Epub 2015 May 27. HSS J. 2015. PMID: 26140037 Free PMC article. No abstract available.
-
Fabrication and characterization of Ti-12Mo/xAl2O3 bio-inert composite for dental prosthetic applications.Front Bioeng Biotechnol. 2024 Jul 15;12:1412586. doi: 10.3389/fbioe.2024.1412586. eCollection 2024. Front Bioeng Biotechnol. 2024. PMID: 39081331 Free PMC article.
-
Recurrent catastrophic ceramic femoral head failure in total hip arthroplasty.Case Rep Orthop. 2014;2014:837954. doi: 10.1155/2014/837954. Epub 2014 Jun 4. Case Rep Orthop. 2014. PMID: 24991441 Free PMC article.
-
Biological response to prosthetic debris.World J Orthop. 2015 Mar 18;6(2):172-89. doi: 10.5312/wjo.v6.i2.172. eCollection 2015 Mar 18. World J Orthop. 2015. PMID: 25793158 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous